Effectiveness of conventional municipal wastewater treatment plants in microplastics removal: Insights from multiple analytical techniques

This study investigated microplastics (MPs) sized 10-5000 µm across stages of a conventional municipal wastewater treatment plant using multiple analytical techniques. Samples were collected via pumping and filtration, treated with the Fenton reaction for wet peroxidation, and separated by density separation. Analysis employed Focal Plane Array Micro-Fourier Transform Infrared Spectroscopy (FPA micro-FTIR), a widely used technique in MPs analysis, alongside the less common Laser Direct Infrared Spectroscopy (LDIR), providing complementary data on particle composition, shape, size, and colour. To enhance insights, spectroscopic methods were supplemented with Thermal Desorption Gas Chromatography-Mass Spectrometry (TD-GC/MS), calibrated for specific polymers, to quantify MPs by mass and assess removal efficiency. Wastewater treatment effectively reduced MPs. In influent samples, concentrations reached 72 MPs/L (FTIR), 2117 MPs/L (LDIR), and 177 µg/L (TD-GC/MS). Primary treatments removed 41 %-55 %, while the wastewater treatment plant effluent contained 1 MPs/L (FTIR), 93 MPs/L (LDIR), and 2 µg/L (TD-GC/MS), reflecting 96 %-99 % removal efficiency. Activated sludge showed concentrations of 123 MPs/L (FTIR), 10,800 MPs/L (LDIR), and 0.3 mg/g dry weight (TD-GC/MS), underscoring its role in MPs capture. However, sludge dewatering released significant MPs into centrifuge rejected water: 484 MPs/L (FTIR), 23,000 MPs/L (LDIR), and 1100 µg/L (TD-GC/MS). These results highlight the effectiveness of conventional treatments in MPs removal and the critical role of sludge in capturing these contaminants. However, sludge dewatering poses a risk of reintroducing MPs into the environment. Effective sludge management should prioritize nutrient recovery and biomass valorisation to mitigate these risks and minimise harmful environmental impacts.

Authors

Institutions

Publication Details

Journal
Journal of Environmental Sciences
Published
2025-04-15
DOI
https://doi.org/10.1016/j.jes.2025.04.035
Citations
4
Primary Topic
Microplastics and Plastic Pollution
Type
article
Field-Weighted Citation Impact
2.01
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effectiveness of conventional municipal wastewater treatment plants in microplastics removal: Insights from multiple analytical techniques

Werner Tirler, Alessandra Cincinelli, Riccardo Gori, David Chelazzi et al.
4 citations
Journal of Environmental Sciences
Microplastics and Plastic Pollution
2.01
article

Effectiveness of conventional municipal wastewater treatment plants in microplastics removal: Insights from multiple analytical techniques

Werner Tirler, Alessandra Cincinelli, Riccardo Gori, David Chelazzi, Tania Martellini, Karen Mair, Costanza Scopetani, Gianni Andreottola, Massimo Donegà, Simone Cavazzoli, Emiliano Carretti, Miriam Ascolese
article en
4 citations

Abstract

This study investigated microplastics (MPs) sized 10-5000 µm across stages of a conventional municipal wastewater treatment plant using multiple analytical techniques. Samples were collected via pumping and filtration, treated with the Fenton reaction for wet peroxidation, and separated by density separation. Analysis employed Focal Plane Array Micro-Fourier Transform Infrared Spectroscopy (FPA micro-FTIR), a widely used technique in MPs analysis, alongside the less common Laser Direct Infrared Spectroscopy (LDIR), providing complementary data on particle composition, shape, size, and colour. To enhance insights, spectroscopic methods were supplemented with Thermal Desorption Gas Chromatography-Mass Spectrometry (TD-GC/MS), calibrated for specific polymers, to quantify MPs by mass and assess removal efficiency. Wastewater treatment effectively reduced MPs. In influent samples, concentrations reached 72 MPs/L (FTIR), 2117 MPs/L (LDIR), and 177 µg/L (TD-GC/MS). Primary treatments removed 41 %-55 %, while the wastewater treatment plant effluent contained 1 MPs/L (FTIR), 93 MPs/L (LDIR), and 2 µg/L (TD-GC/MS), reflecting 96 %-99 % removal efficiency. Activated sludge showed concentrations of 123 MPs/L (FTIR), 10,800 MPs/L (LDIR), and 0.3 mg/g dry weight (TD-GC/MS), underscoring its role in MPs capture. However, sludge dewatering released significant MPs into centrifuge rejected water: 484 MPs/L (FTIR), 23,000 MPs/L (LDIR), and 1100 µg/L (TD-GC/MS). These results highlight the effectiveness of conventional treatments in MPs removal and the critical role of sludge in capturing these contaminants. However, sludge dewatering poses a risk of reintroducing MPs into the environment. Effective sludge management should prioritize nutrient recovery and biomass valorisation to mitigate these risks and minimise harmful environmental impacts.

Journal of Environmental SciencesVol. 160
University of Trento (IT), Ospedale di Bolzano (IT), Consorzio Interuniversitario per lo Sviluppo dei Sistemi a Grande Interfase (IT), Fundación para el Desarrollo de la Ecología (BO), University of Florence (IT)
Clean water and sanitation
Openalex Percentile: Top 15%
Microplastics and Plastic Pollution
2.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.