Graphene-enhanced Raman spectroscopy in ultra-low concentrations of pharmaceuticals

In this work, we provide a novel metrology method to detect the presence of ultra-low concentrations of ibuprofen and paracetamol dissolved in water by Raman spectroscopy. We have deposited a single microdrop of the contaminated water solution onto a graphene substrate. We found that low concentrations of pharmaceuticals trigger a Graphene Surface Enhanced Raman Spectroscopy response allowing for the detection of pharmaceuticals in the low concentration limit of 100 μ g /mL. The enhancement factor observed for GERS in the G- and 2D lines reached up to 48 times derived from the molecular interaction of both molecules (graphene and the pharmaceutical), and 200 times for the D-line. Thus, we observed that the graphene monolayer enhances the pharmaceutical bands and quenches its fluorescence, allowing the identification of the pharmaceutical characteristic spectrum, which can be employed as a bio-marker of the pharmaceutical molecular presence. Finally, we performed a high-temperature treatment in vacuum conditions to study the recovery of graphene. After the thermal treatment, no contributions from ibuprofen were evident by Raman spectroscopy, but a high functionalization/oxidation stage. The conductivity of the graphene surface was also analyzed and it showed: (I) a decrease in the conductivity after the deposition of the pharmaceutical, and (II) a recovered conductance after the thermal treatment, which indicates a partial recovery of the substrate’s properties. This project brings an innovative tool for the detection of ultra-low concentrated pharmaceuticals when deposited on graphene. This discovery opens doors to a better understanding of the pollutant sources that will potentially contribute to the preservation of public sanity, pharmaceutical pollution research, and water quality monitoring in developing countries like Ecuador. • Graphene Enhanced Raman Spectroscopy driven by pharmaceuticals. • Detection of ultra-low concentrations of pharmaceuticals dissolved in water. • Stronguest GERS response evinced by the double resonance of graphene.

Authors

Institutions

Publication Details

Journal
Carbon Trends
Published
2025-04-15
DOI
https://doi.org/10.1016/j.cartre.2025.100505
Citations
2
Primary Topic
Spectroscopy Techniques in Biomedical and Chemical Research
Type
article
Field-Weighted Citation Impact
3.27
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Graphene-enhanced Raman spectroscopy in ultra-low concentrations of pharmaceuticals

María Fernanda Bósquez‐Cáceres, Julio C. Chacón‐Torres, Nayeli Y. Gómez-Castillo, Nardy J. Sallo-Chabla et al.
2 citations
Carbon Trends
Spectroscopy Techniques in Biomedical and Chemical Research
3.27
article

Graphene-enhanced Raman spectroscopy in ultra-low concentrations of pharmaceuticals

María Fernanda Bósquez‐Cáceres, Julio C. Chacón‐Torres, Nayeli Y. Gómez-Castillo, Nardy J. Sallo-Chabla, Daniela Pérez-Zárate
article en
2 citations

Abstract

In this work, we provide a novel metrology method to detect the presence of ultra-low concentrations of ibuprofen and paracetamol dissolved in water by Raman spectroscopy. We have deposited a single microdrop of the contaminated water solution onto a graphene substrate. We found that low concentrations of pharmaceuticals trigger a Graphene Surface Enhanced Raman Spectroscopy response allowing for the detection of pharmaceuticals in the low concentration limit of 100 μ g /mL. The enhancement factor observed for GERS in the G- and 2D lines reached up to 48 times derived from the molecular interaction of both molecules (graphene and the pharmaceutical), and 200 times for the D-line. Thus, we observed that the graphene monolayer enhances the pharmaceutical bands and quenches its fluorescence, allowing the identification of the pharmaceutical characteristic spectrum, which can be employed as a bio-marker of the pharmaceutical molecular presence. Finally, we performed a high-temperature treatment in vacuum conditions to study the recovery of graphene. After the thermal treatment, no contributions from ibuprofen were evident by Raman spectroscopy, but a high functionalization/oxidation stage. The conductivity of the graphene surface was also analyzed and it showed: (I) a decrease in the conductivity after the deposition of the pharmaceutical, and (II) a recovered conductance after the thermal treatment, which indicates a partial recovery of the substrate’s properties. This project brings an innovative tool for the detection of ultra-low concentrated pharmaceuticals when deposited on graphene. This discovery opens doors to a better understanding of the pollutant sources that will potentially contribute to the preservation of public sanity, pharmaceutical pollution research, and water quality monitoring in developing countries like Ecuador. • Graphene Enhanced Raman Spectroscopy driven by pharmaceuticals. • Detection of ultra-low concentrations of pharmaceuticals dissolved in water. • Stronguest GERS response evinced by the double resonance of graphene.

Carbon TrendsVol. 20
Universidad Yachay Tech (EC)
Openalex Percentile: Top 9%
Spectroscopy Techniques in Biomedical and Chemical Research
3.27
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.