Geoelectric Assessment of Regolith Aquifer and Its Vulnerability, in a Typical Basement Complex Terrain, Southwestern Nigeria

Assessment of groundwater potential cum regolith aquifer protective strength was carried out using the electrical resistivity method at Ikole Ekiti, Southwestern Nigeria, to assess its viability and susceptibility. The Vertical Electrical Sounding (VES) technique using the Schlumberger array was adopted. The acquired data was partially curve-matched, forward-modelled, and iterated using WinResist version 1.0 software. Charts, para sections, tables, and maps were generated from the results obtained to aid interpretations. The KH curve type, which indicates good protective capacity, is more predominant in the study area than other curve types. Parasections showed four (4) geoelectric layers, i.e., topsoil, upper saprolite, lower saprolite, and sap rock. A weathered layer is the principal aquifer unit identified in the area; it is appreciably thick, and the basement is fresh. The thickness of regolith ranges from 2 to 56 m, with an appreciable thickness that can sustain moderate groundwater yield in the southern region of Ikole. The layer above the regolith aquifer has an average thickness slightly below 20 m; therefore, areas without lateritic cover will be prone to pollution. The strength of the regolith aquifer was assessed by employing longitudinal conductance (LC) and Geoelectric Layer Susceptibility Index (GLSI) ratings. The inherent weakness of the LC rating (not accounting for the lateritic nature of soil) was complemented by the GLSI rating. The southern region of the study area where groundwater is feasible is evaluated to have moderate protective capacity. Therefore, sources of pollution, such as septic tanks and dump sites, should be located far away from the area.

Authors

Institutions

Publication Details

Journal
Malaysian Journal of Science
Published
2025-03-28
DOI
https://doi.org/10.22452/mjs.vol44no1.6
Primary Topic
Geophysical and Geoelectrical Methods
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Geoelectric Assessment of Regolith Aquifer and Its Vulnerability, in a Typical Basement Complex Terrain, Southwestern Nigeria

Wilfred N. Igboama, Morufu T. Aroyehun, O.S. Hammed
Malaysian Journal of Science
Geophysical and Geoelectrical Methods
article

Geoelectric Assessment of Regolith Aquifer and Its Vulnerability, in a Typical Basement Complex Terrain, Southwestern Nigeria

Wilfred N. Igboama, Morufu T. Aroyehun, O.S. Hammed
article en

Abstract

Assessment of groundwater potential cum regolith aquifer protective strength was carried out using the electrical resistivity method at Ikole Ekiti, Southwestern Nigeria, to assess its viability and susceptibility. The Vertical Electrical Sounding (VES) technique using the Schlumberger array was adopted. The acquired data was partially curve-matched, forward-modelled, and iterated using WinResist version 1.0 software. Charts, para sections, tables, and maps were generated from the results obtained to aid interpretations. The KH curve type, which indicates good protective capacity, is more predominant in the study area than other curve types. Parasections showed four (4) geoelectric layers, i.e., topsoil, upper saprolite, lower saprolite, and sap rock. A weathered layer is the principal aquifer unit identified in the area; it is appreciably thick, and the basement is fresh. The thickness of regolith ranges from 2 to 56 m, with an appreciable thickness that can sustain moderate groundwater yield in the southern region of Ikole. The layer above the regolith aquifer has an average thickness slightly below 20 m; therefore, areas without lateritic cover will be prone to pollution. The strength of the regolith aquifer was assessed by employing longitudinal conductance (LC) and Geoelectric Layer Susceptibility Index (GLSI) ratings. The inherent weakness of the LC rating (not accounting for the lateritic nature of soil) was complemented by the GLSI rating. The southern region of the study area where groundwater is feasible is evaluated to have moderate protective capacity. Therefore, sources of pollution, such as septic tanks and dump sites, should be located far away from the area.

Malaysian Journal of ScienceVol. 44(1)
Federal University Oye Ekiti (NG)
Openalex Percentile: Top 89%
Geophysical and Geoelectrical Methods
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.