Validation of a novel CT perfusion software compared to RAPID in stroke patients receiving endovascular therapy

Accurate estimate of ischemic core volume (ICV) and penumbra volume (PV) is important in decision-making for endovascular therapies (EVT) and predicting the patient's clinical outcome. In this study, we compared the performance of a novel automated CT perfusion software UGuard and the Rapid Processing of Perfusion and Diffusion (RAPID). UGuard and RAPID had strong agreement with regard to ICV (ICC 0.92, 95% CI 0.89 - 0.94) and PV (ICC 0.8, 95% CI 0.73 - 0.85) measurements. ICVs measured by UGuard or RAPID were similar in predicting favorable outcome (AUC 0.72 vs. 0.70, P = 0.43), with UGuard measurements having higher specificity. After adjusting for significant clinical covariates, the predictive performance of favorable outcome was excellent for each of the six models incorporating ICV and PV, and the model which incorporated ICV and PV measured by UGuard software package showed the best predictive performance. We concluded that the ICV and PV of CT perfusion images measured by UGuard software package, as well as the capacity to predict favorable outcome of patients following EVT, were comparable to RAPID.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-04-15
DOI
https://doi.org/10.1038/s41598-025-96340-9
Citations
2
Primary Topic
Acute Ischemic Stroke Management
Type
article
Field-Weighted Citation Impact
2.71

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Validation of a novel CT perfusion software compared to RAPID in stroke patients receiving endovascular therapy

Tingyu Yi, Yang Zhang, Bowen Deng, Luyun Zhang et al.
2 citations
Scientific Reports
Acute Ischemic Stroke Management
2.71
article

Validation of a novel CT perfusion software compared to RAPID in stroke patients receiving endovascular therapy

Tingyu Yi, Yang Zhang, Bowen Deng, Luyun Zhang, Xue Bai, Yi Sui, Yanting Chang, D.W. Chen, Wenhuo Chen, Yu Wang, Xinze Guo, Tingting Qiu, Thanh N. Nguyen, Yang Zhao
article en
2 citations

Abstract

Accurate estimate of ischemic core volume (ICV) and penumbra volume (PV) is important in decision-making for endovascular therapies (EVT) and predicting the patient's clinical outcome. In this study, we compared the performance of a novel automated CT perfusion software UGuard and the Rapid Processing of Perfusion and Diffusion (RAPID). UGuard and RAPID had strong agreement with regard to ICV (ICC 0.92, 95% CI 0.89 - 0.94) and PV (ICC 0.8, 95% CI 0.73 - 0.85) measurements. ICVs measured by UGuard or RAPID were similar in predicting favorable outcome (AUC 0.72 vs. 0.70, P = 0.43), with UGuard measurements having higher specificity. After adjusting for significant clinical covariates, the predictive performance of favorable outcome was excellent for each of the six models incorporating ICV and PV, and the model which incorporated ICV and PV measured by UGuard software package showed the best predictive performance. We concluded that the ICV and PV of CT perfusion images measured by UGuard software package, as well as the capacity to predict favorable outcome of patients following EVT, were comparable to RAPID.

Scientific ReportsVol. 15(1)
Shenyang Medical College (CN), Boston University (US), Boston Medical Center (US), Fujian Medical University (CN), Zhangzhou Municipal Hospital of Fujian Province (CN)
Shenyang Science and Technology Bureau, Fujian Medical University
Good health and well-being
Openalex Percentile: Top 11%
Acute Ischemic Stroke Management
2.71
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.