FEA‐Based Optimisation of an Inserted‐Shunt Integrated Planar Transformer for a Bidirectional CLLLC Resonant Converter

ABSTRACT This paper presents an optimisation method for an inserted‐shunt integrated planar transformer based on 3D simulation in Ansys Maxwell. The optimisation objective is enhanced efficiency and power density for the transformer. Thermal analysis verifies the optimisation to ensure the transformer's operability under limited temperature conditions when its size is reduced. The optimised integrated transformer is implemented for verification, with the presentation of experimental results, including AC resistance, efficiency, operating waveforms, and thermal imagery. Furthermore, the paper provides insight into the loss distribution of the transformer. The study shows that the optimisation enhances the power density of the inserted‐shunt integrated planar transformer by 270% compared to the conventional design. Additionally, the CLLLC converter incorporating the optimised transformer achieves approximately 1.84 percentage points higher efficiency than the conventional design.

Authors

Institutions

Publication Details

Journal
IET Power Electronics
Published
2025-01-01
DOI
https://doi.org/10.1049/pel2.70014
Primary Topic
Advanced DC-DC Converters
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

FEA‐Based Optimisation of an Inserted‐Shunt Integrated Planar Transformer for a Bidirectional CLLLC Resonant Converter

Sajad Arab Ansari, Martin P. Foster, Jonathan N. Davidson
IET Power Electronics
Advanced DC-DC Converters
article

FEA‐Based Optimisation of an Inserted‐Shunt Integrated Planar Transformer for a Bidirectional CLLLC Resonant Converter

Sajad Arab Ansari, Martin P. Foster, Jonathan N. Davidson
article en

Abstract

ABSTRACT This paper presents an optimisation method for an inserted‐shunt integrated planar transformer based on 3D simulation in Ansys Maxwell. The optimisation objective is enhanced efficiency and power density for the transformer. Thermal analysis verifies the optimisation to ensure the transformer's operability under limited temperature conditions when its size is reduced. The optimised integrated transformer is implemented for verification, with the presentation of experimental results, including AC resistance, efficiency, operating waveforms, and thermal imagery. Furthermore, the paper provides insight into the loss distribution of the transformer. The study shows that the optimisation enhances the power density of the inserted‐shunt integrated planar transformer by 270% compared to the conventional design. Additionally, the CLLLC converter incorporating the optimised transformer achieves approximately 1.84 percentage points higher efficiency than the conventional design.

IET Power ElectronicsVol. 18(1)
University of Sheffield (GB)
Engineering and Physical Sciences Research Council
Openalex Percentile: Top 94%
Advanced DC-DC Converters
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

FEA‐Based Optimisation of an Inserted‐Shunt Integrated Planar Transformer for a Bidirectional CLLLC Resonant Converter — Sajad Arab Ansari, Martin P. Foster, et al. · IET Power Electronics (2025) | TGRS Research Map | TGRS