DEVELOPMENT OF A PROCEDURE FOR INCREASING THE ACCURACY OF THE RECONSTRUCTION AND TRIANGULATION PROCESS OF THE CRANIAL VAULT GEOMETRY FOR ADDITIVE MANUFACTURING

CT scanners installed in clinics used different slice thicknesses, which usually produce data with an anisotropic structure of voxels. The low visual quality results are due to the discontinuous interpolation between neighboring voxels, resulting in a very “blocky” appearance of the reconstructed surfaces (stair-step artifact). This structure can also directly affect the volume, geometry, and linear accuracy of digital and physical 3D models. The article presents a method that improves the design of cranial vault models for additive manufacturing after the staircase artifact has occurred. The research was performed on 14 different patients (seven males and seven females). Changing the slice thickness from 2.4 mm to 4.8 mm generated over 90% errors in reconstructing the cranial vault area in the range of 0.830 mm +/- 1.364 mm (mean deviation +/- expanded uncertainty) for males and 0.780 mm +/- 1.338 mm for females. To increase the spatial resolution of the digital imaging data, an interpolation process was performed on 2D radiographic images. After using the data interpolation procedure (Lanczos filter), deviations were mainly in the range of 0.465 mm +/- 1.038 mm for males and 0.328 mm +/- 0.842 mm for females. The last stage of the improved process involved mesh optimization. Utilizing Laplacian smoothing surface and isotropic polygonal remesh, this procedure decreased global error, especially in regions with high curvatures. Over 90% of the analyzed points after using the Lanczos filter and optimization mesh procedure are within the range of 0.338 mm +/- 1.014 mm for males and 0.301 mm +/- 0.806 mm for females.

Authors

Publication Details

Journal
Facta Universitatis Series Mechanical Engineering
Published
2025-04-11
DOI
https://doi.org/10.22190/fume211208025t
Citations
6
Primary Topic
Engineering Technology and Methodologies
Type
article
Field-Weighted Citation Impact
3.73
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

DEVELOPMENT OF A PROCEDURE FOR INCREASING THE ACCURACY OF THE RECONSTRUCTION AND TRIANGULATION PROCESS OF THE CRANIAL VAULT GEOMETRY FOR ADDITIVE MANUFACTURING

P. Turek, Grzegorz Budzik
6 citations
Facta Universitatis Series Mechanical Engineering
Engineering Technology and Methodologies
3.73
article

DEVELOPMENT OF A PROCEDURE FOR INCREASING THE ACCURACY OF THE RECONSTRUCTION AND TRIANGULATION PROCESS OF THE CRANIAL VAULT GEOMETRY FOR ADDITIVE MANUFACTURING

P. Turek, Grzegorz Budzik
article en
6 citations

Abstract

CT scanners installed in clinics used different slice thicknesses, which usually produce data with an anisotropic structure of voxels. The low visual quality results are due to the discontinuous interpolation between neighboring voxels, resulting in a very “blocky” appearance of the reconstructed surfaces (stair-step artifact). This structure can also directly affect the volume, geometry, and linear accuracy of digital and physical 3D models. The article presents a method that improves the design of cranial vault models for additive manufacturing after the staircase artifact has occurred. The research was performed on 14 different patients (seven males and seven females). Changing the slice thickness from 2.4 mm to 4.8 mm generated over 90% errors in reconstructing the cranial vault area in the range of 0.830 mm +/- 1.364 mm (mean deviation +/- expanded uncertainty) for males and 0.780 mm +/- 1.338 mm for females. To increase the spatial resolution of the digital imaging data, an interpolation process was performed on 2D radiographic images. After using the data interpolation procedure (Lanczos filter), deviations were mainly in the range of 0.465 mm +/- 1.038 mm for males and 0.328 mm +/- 0.842 mm for females. The last stage of the improved process involved mesh optimization. Utilizing Laplacian smoothing surface and isotropic polygonal remesh, this procedure decreased global error, especially in regions with high curvatures. Over 90% of the analyzed points after using the Lanczos filter and optimization mesh procedure are within the range of 0.338 mm +/- 1.014 mm for males and 0.301 mm +/- 0.806 mm for females.

Facta Universitatis Series Mechanical Engineering
Openalex Percentile: Top 7%
Engineering Technology and Methodologies
3.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.