Interval Estimates of the Total Content of Antioxidants for Different Analytical Assays

Determination of the total content (сΣ) of similar analytes recalculated to a standard substance Xst is a commonly used but a metrologically incorrect measuring procedure, leading to significant systematic errors (B-type uncertainty). Interval estimate сΣ (Vershinin et al., 2016) is an alternative method that does not require recalculation to Xst and, in contrast to calculating total indices, slightly depends on the nature and ratio of the sought-for group components present in the sample. Such estimates are used for evaluating the total content of antioxidants (AOs) of foodstuffs. However, the dependence of these estimates on the choice of the group reagent and the signal measuring procedure is uncertain. To address this question, model mixtures of AOs with known сΣ values, ranging from 10–5 to 10–4 mol/L, were prepared and tested. Generalized signals were measured by spectrophotometry using Folin–Ciocâlteu (F–C) and FRAP assays, and traditional and interval estimates of сΣ were calculated and compared. The true values of сΣ were within the respective intervals for all model mixtures; in the case of the F–C assay, the intervals were wider and shifted towards higher сΣ values. The FRAP assay was modified using AO concentrations in mol-eq/L, reducing reaction time, and substituting the auxiliary reagent. This modification successfully brought the sensitivity coefficients of individual AOs closer to one another and made the relative widths of intervals three times narrower. Modified FRAP assay was used for the group analysis of wines, black tea infusions, and juices. Corresponding interval estimates of сΣ were obtained and compared. The unresolved issues and future research directions related to interval estimates are discussed.

Authors

Institutions

Publication Details

Journal
Journal of Analytical Chemistry
Published
2025-01-01
DOI
https://doi.org/10.1134/s1061934824701508
Primary Topic
Computational Drug Discovery Methods
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Interval Estimates of the Total Content of Antioxidants for Different Analytical Assays

В. И. Вершинин
Journal of Analytical Chemistry
Computational Drug Discovery Methods
article

Interval Estimates of the Total Content of Antioxidants for Different Analytical Assays

В. И. Вершинин
article en

Abstract

Determination of the total content (сΣ) of similar analytes recalculated to a standard substance Xst is a commonly used but a metrologically incorrect measuring procedure, leading to significant systematic errors (B-type uncertainty). Interval estimate сΣ (Vershinin et al., 2016) is an alternative method that does not require recalculation to Xst and, in contrast to calculating total indices, slightly depends on the nature and ratio of the sought-for group components present in the sample. Such estimates are used for evaluating the total content of antioxidants (AOs) of foodstuffs. However, the dependence of these estimates on the choice of the group reagent and the signal measuring procedure is uncertain. To address this question, model mixtures of AOs with known сΣ values, ranging from 10–5 to 10–4 mol/L, were prepared and tested. Generalized signals were measured by spectrophotometry using Folin–Ciocâlteu (F–C) and FRAP assays, and traditional and interval estimates of сΣ were calculated and compared. The true values of сΣ were within the respective intervals for all model mixtures; in the case of the F–C assay, the intervals were wider and shifted towards higher сΣ values. The FRAP assay was modified using AO concentrations in mol-eq/L, reducing reaction time, and substituting the auxiliary reagent. This modification successfully brought the sensitivity coefficients of individual AOs closer to one another and made the relative widths of intervals three times narrower. Modified FRAP assay was used for the group analysis of wines, black tea infusions, and juices. Corresponding interval estimates of сΣ were obtained and compared. The unresolved issues and future research directions related to interval estimates are discussed.

Journal of Analytical ChemistryVol. 80(1)
Omsk State University (RU)
Zero hunger
Openalex Percentile: Top 91%
Computational Drug Discovery Methods
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Interval Estimates of the Total Content of Antioxidants for Different Analytical Assays — В. И. Вершинин · Journal of Analytical Chemistry (2025) | TGRS Research Map | TGRS