Nondestructive Control of Medicines by a Colormetric Method Using a Smartphone and the PhotoMetrix PRO® Application

The non-destructive control of levofloxacin, non-steroidal anti-inflammatory drugs, acetylsalicylic acid, and vinpocetine in medicines by their intrinsic fluorescence and diffuse reflectance of near-IR radiation using a smartphone and a 3D-printed device is proposed. Blister packs and tablet shells slightly reduce the intensity of the diffuse reflectance signal at a wavelength of 850 nm and fluorescence due to UV irradiation (390 nm), which is confirmed by a comparative analysis of the results of colorimetric measurement in samples of medicines in blister packs, without packs, and on a tablet split. A correlation is observed between the analytical signal and the mass of the active substance regardless of the study version. The data array was processed using principal component analysis (PCA), hierarchical cluster analysis (HCA), and partial least squares (PLS) regression methods using the PhotoMetrix PRO® smartphone software. It was shown that these algorithms can be used to identify drugs by their manufacturer and to determine the mass of active substances in tablets. Colorimetric signals from tablets from one manufacturer form separate clusters on dendrograms created using the HCA algorithm. The data obtained using PCA indicate the location of signals from tablets from different manufacturers in separate quadrants, which facilitates the identification of a pharmaceutical company. The use of chemometric analysis methods for determining the mass of the active substance in tablets is considered. The relative standard deviation of the analysis results does not exceed 0.04. The relative error of the analysis results does not exceed the recommended values for the preparation of medicines according to the Order of the Ministry of Health of the Russian Federation dated October 26, 2015 No. 751n.

Authors

Institutions

Publication Details

Journal
Journal of Analytical Chemistry
Published
2025-01-01
DOI
https://doi.org/10.1134/s1061934824701533
Primary Topic
Innovative Microfluidic and Catalytic Techniques Innovation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Nondestructive Control of Medicines by a Colormetric Method Using a Smartphone and the PhotoMetrix PRO® Application

В. Г. Амелин, O. E. Emel’yanov
Journal of Analytical Chemistry
Innovative Microfluidic and Catalytic Techniques Innovation
article

Nondestructive Control of Medicines by a Colormetric Method Using a Smartphone and the PhotoMetrix PRO® Application

В. Г. Амелин, O. E. Emel’yanov
article en

Abstract

The non-destructive control of levofloxacin, non-steroidal anti-inflammatory drugs, acetylsalicylic acid, and vinpocetine in medicines by their intrinsic fluorescence and diffuse reflectance of near-IR radiation using a smartphone and a 3D-printed device is proposed. Blister packs and tablet shells slightly reduce the intensity of the diffuse reflectance signal at a wavelength of 850 nm and fluorescence due to UV irradiation (390 nm), which is confirmed by a comparative analysis of the results of colorimetric measurement in samples of medicines in blister packs, without packs, and on a tablet split. A correlation is observed between the analytical signal and the mass of the active substance regardless of the study version. The data array was processed using principal component analysis (PCA), hierarchical cluster analysis (HCA), and partial least squares (PLS) regression methods using the PhotoMetrix PRO® smartphone software. It was shown that these algorithms can be used to identify drugs by their manufacturer and to determine the mass of active substances in tablets. Colorimetric signals from tablets from one manufacturer form separate clusters on dendrograms created using the HCA algorithm. The data obtained using PCA indicate the location of signals from tablets from different manufacturers in separate quadrants, which facilitates the identification of a pharmaceutical company. The use of chemometric analysis methods for determining the mass of the active substance in tablets is considered. The relative standard deviation of the analysis results does not exceed 0.04. The relative error of the analysis results does not exceed the recommended values for the preparation of medicines according to the Order of the Ministry of Health of the Russian Federation dated October 26, 2015 No. 751n.

Journal of Analytical ChemistryVol. 80(1)
Vladimir State University (RU), All-Russian State Scientific Research Institute for Control, Standardization and Certification of Veterinary Preparations (RU)
Openalex Percentile: Top 93%
Innovative Microfluidic and Catalytic Techniques Innovation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.