Purpose: To evaluate the compatibility and usability of test results obtained from the IDRA and Keratograph 5M in clinical settings by comparing their performance in patients with dry eye disease.Methods: From December 27 to 30, 2022, a study was conducted on 30 patients diagnosed with dry eye utilizing both the Keratograph 5M and IDRA devices. The parameters compared and analyzed included lipid layer thickness, tear meniscus height, tear film break-up time, and meibography. A paired t-test was used for statistical comparison. The lipid layer thickness in the Keratograph 5M was graded on a scale from 0 to 4 based on thickness.Results: No significant differences were found between the two devices in tear film break-up time, tear meniscus height, and meibography (<i>p</i> = 0.148, 0.072, 0.124, respectively). However, the tear lipid layer thickness measured by IDRA showed a proportional relationship with the grade assigned by the Keratograph 5M (Kendall R = 0.217, <i>p</i> = 0.037; Spearman R = 0.260, <i>p</i> = 0.045).Conclusions: The IDRA device offers the advantage of performing multiple dry eye tests; simultaneously, thereby saving time compared to the Keratograph 5M. Both devices can be used compatibly with IDRA particularly advantageous for providing a numerical value for tear lipid layer thickness which enhances the convenience of dry eye diagnosis and treatment.

Authors

Publication Details

Journal
Journal of the Korean Ophthalmological Society
Published
2025-04-15
DOI
https://doi.org/10.3341/jkos.2025.66.4.175
Primary Topic
Ocular Surface and Contact Lens
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Comparison between Keratograph 5M® and IDRA® in Dry Eye Patients

Ho Ra, Ho Sik Hwang, Kyung‐Sun Na, Ha-Rim So et al.
Journal of the Korean Ophthalmological Society
Ocular Surface and Contact Lens
article

A Comparison between Keratograph 5M® and IDRA® in Dry Eye Patients

Ho Ra, Ho Sik Hwang, Kyung‐Sun Na, Ha-Rim So, Soo Bin Park, Jiwon Baek, Hyun Seung Kim, Eun Chul Kim, Nam Yeo Kang
article en

Abstract

Purpose: To evaluate the compatibility and usability of test results obtained from the IDRA and Keratograph 5M in clinical settings by comparing their performance in patients with dry eye disease.Methods: From December 27 to 30, 2022, a study was conducted on 30 patients diagnosed with dry eye utilizing both the Keratograph 5M and IDRA devices. The parameters compared and analyzed included lipid layer thickness, tear meniscus height, tear film break-up time, and meibography. A paired t-test was used for statistical comparison. The lipid layer thickness in the Keratograph 5M was graded on a scale from 0 to 4 based on thickness.Results: No significant differences were found between the two devices in tear film break-up time, tear meniscus height, and meibography (<i>p</i> = 0.148, 0.072, 0.124, respectively). However, the tear lipid layer thickness measured by IDRA showed a proportional relationship with the grade assigned by the Keratograph 5M (Kendall R = 0.217, <i>p</i> = 0.037; Spearman R = 0.260, <i>p</i> = 0.045).Conclusions: The IDRA device offers the advantage of performing multiple dry eye tests; simultaneously, thereby saving time compared to the Keratograph 5M. Both devices can be used compatibly with IDRA particularly advantageous for providing a numerical value for tear lipid layer thickness which enhances the convenience of dry eye diagnosis and treatment.

Journal of the Korean Ophthalmological SocietyVol. 66(4)
Openalex Percentile: Top 89%
Ocular Surface and Contact Lens
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.