Anatomy-inspired model for critical landmark localization in 3D spinal ultrasound volume data

Three-dimensional (3D) spinal ultrasound imaging has demonstrated its promising potential in measuring spinal deformity through recent studies, and it is more suitable for massive early screening and longitudinal follow-up of adolescent idiopathic scoliosis (AIS) compared with X-ray imaging due to its radiation-free superiority. Moreover, some deformities with low observability, such as vertebral rotation, in X-ray images can also be reflected by critical landmarks in 3D ultrasound data. In this paper, we propose a localization network (LLNet) to extract lamina in 3D ultrasound data, which has been indicated as a meaningful anatomy for measuring vertebral rotation by clinical studies. First, the LLNet skillfully establishes a parallel anatomical prior embedding branch that implicitly explores the anatomical correlation between the lamina and another anatomy with more stable observability (spinous process) during the training phase and then introduces the correlation to highlight the potential region of the lamina in the inferring one. Second, since the lamina is a tiny target, the information loss caused by continuous convolutional and pooling operations has a profound negative effect on detecting the lamina. We employ an optimization mechanism to mitigate this problem, which refines feature maps according to information from the original image and further reuses them to polish output. Furthermore, a modified global-local attention module is deployed on skip connections to mine global dependencies and contextual information to construct an effective image pattern. Extensive comparisons and ablation studies are performed on actual clinical data. Results indicate that the capability of our model is better than other outstanding detection models, and functional modules effectively contribute to this, with a 100.0 % detection success rate and an 8.9 % improvement of mean intersection over the union. Thus, our model is promising to become a helpful part of a computer-assisted diagnosis system based on 3D spinal ultrasound imaging.

Authors

Institutions

Publication Details

Journal
Medical Image Analysis
Published
2025-04-15
DOI
https://doi.org/10.1016/j.media.2025.103610
Primary Topic
Medical Imaging and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Anatomy-inspired model for critical landmark localization in 3D spinal ultrasound volume data

Yi Huang, Jinhua Yu, Yuanyuan Wang, Yong‐Ping Zheng et al.
Medical Image Analysis
Medical Imaging and Analysis
article

Anatomy-inspired model for critical landmark localization in 3D spinal ultrasound volume data

Yi Huang, Jinhua Yu, Yuanyuan Wang, Yong‐Ping Zheng, Jing Jiao
article en

Abstract

Three-dimensional (3D) spinal ultrasound imaging has demonstrated its promising potential in measuring spinal deformity through recent studies, and it is more suitable for massive early screening and longitudinal follow-up of adolescent idiopathic scoliosis (AIS) compared with X-ray imaging due to its radiation-free superiority. Moreover, some deformities with low observability, such as vertebral rotation, in X-ray images can also be reflected by critical landmarks in 3D ultrasound data. In this paper, we propose a localization network (LLNet) to extract lamina in 3D ultrasound data, which has been indicated as a meaningful anatomy for measuring vertebral rotation by clinical studies. First, the LLNet skillfully establishes a parallel anatomical prior embedding branch that implicitly explores the anatomical correlation between the lamina and another anatomy with more stable observability (spinous process) during the training phase and then introduces the correlation to highlight the potential region of the lamina in the inferring one. Second, since the lamina is a tiny target, the information loss caused by continuous convolutional and pooling operations has a profound negative effect on detecting the lamina. We employ an optimization mechanism to mitigate this problem, which refines feature maps according to information from the original image and further reuses them to polish output. Furthermore, a modified global-local attention module is deployed on skip connections to mine global dependencies and contextual information to construct an effective image pattern. Extensive comparisons and ablation studies are performed on actual clinical data. Results indicate that the capability of our model is better than other outstanding detection models, and functional modules effectively contribute to this, with a 100.0 % detection success rate and an 8.9 % improvement of mean intersection over the union. Thus, our model is promising to become a helpful part of a computer-assisted diagnosis system based on 3D spinal ultrasound imaging.

Medical Image AnalysisVol. 103
Hong Kong Polytechnic University (HK), Fudan University (CN)
Sustainable cities and communities
Openalex Percentile: Top 93%
Medical Imaging and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.