Preparation, characterisation, and testing of reservoir-based implantable devices loaded with tizanidine and lidocaine

Multiple sclerosis is a chronic neuroimmunological disorder that causes progressive disability, primarily in young adults. It places a significant burden on healthcare systems due to high medication costs and long-term care needs. Implantable devices offer a promising alternative for delivering sustained drug doses in the treatment of chronic conditions. This study introduces a novel long-acting subcutaneous implant for dual-drug delivery: tizanidine (TZ) for spasticity management and lidocaine (LD) for post-insertion pain relief. Reservoir-type implants were developed with TZ in the core and LD in the shell. Two fabrication methods-direct compression and vacuum compression moulding (VCM)-were evaluated for TZ-loaded pellets (3 mm diameter, ~ 10 mm length) using TZ base and TZ hydrochloride. Pellets were encapsulated inside a biodegradable polycaprolactone (PCL) tubular membrane to control drug release. Direct compression pellets, made with poly(vinyl pyrrolidone) and hydroxypropyl-β-cyclodextrin, disintegrated quickly, releasing TZ over 20 days. VCM pellets, formulated with PCL or PCL/poly(ethylene glycol) (PEG), offered prolonged release: up to 200 days for TZ base and 80 days for TZ hydrochloride. Adding PEG accelerated TZ release, reducing duration to 20 days (TZ base) and 125 days (TZ hydrochloride). LD was incorporated into the PCL membrane, providing up to three days of sustained release. Physicochemical analysis confirmed formulation homogeneity and no covalent interactions. These findings highlight the potential of this implant system for MS-related spasticity management, supporting further research into long-acting implants to improve treatment adherence and patient outcomes.

Authors

Institutions

Publication Details

Journal
Drug Delivery and Translational Research
Published
2025-04-15
DOI
https://doi.org/10.1007/s13346-025-01855-3
Citations
4
Primary Topic
Advanced Drug Delivery Systems
Type
article
Field-Weighted Citation Impact
3.16

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Preparation, characterisation, and testing of reservoir-based implantable devices loaded with tizanidine and lidocaine

Eneko Larrañeta, Octavio E. Fandiño, Ryan F. Donnelly, Qonita Kurnia Anjani et al.
4 citations
Drug Delivery and Translational Research
Advanced Drug Delivery Systems
3.16
article

Preparation, characterisation, and testing of reservoir-based implantable devices loaded with tizanidine and lidocaine

Eneko Larrañeta, Octavio E. Fandiño, Ryan F. Donnelly, Qonita Kurnia Anjani, Elizabeth R. Magill, Jonathan G. Acheson, Camila J. Picco, Juan Domínguez‐Robles, Mihir S Bhalerao
article en
4 citations

Abstract

Multiple sclerosis is a chronic neuroimmunological disorder that causes progressive disability, primarily in young adults. It places a significant burden on healthcare systems due to high medication costs and long-term care needs. Implantable devices offer a promising alternative for delivering sustained drug doses in the treatment of chronic conditions. This study introduces a novel long-acting subcutaneous implant for dual-drug delivery: tizanidine (TZ) for spasticity management and lidocaine (LD) for post-insertion pain relief. Reservoir-type implants were developed with TZ in the core and LD in the shell. Two fabrication methods-direct compression and vacuum compression moulding (VCM)-were evaluated for TZ-loaded pellets (3 mm diameter, ~ 10 mm length) using TZ base and TZ hydrochloride. Pellets were encapsulated inside a biodegradable polycaprolactone (PCL) tubular membrane to control drug release. Direct compression pellets, made with poly(vinyl pyrrolidone) and hydroxypropyl-β-cyclodextrin, disintegrated quickly, releasing TZ over 20 days. VCM pellets, formulated with PCL or PCL/poly(ethylene glycol) (PEG), offered prolonged release: up to 200 days for TZ base and 80 days for TZ hydrochloride. Adding PEG accelerated TZ release, reducing duration to 20 days (TZ base) and 125 days (TZ hydrochloride). LD was incorporated into the PCL membrane, providing up to three days of sustained release. Physicochemical analysis confirmed formulation homogeneity and no covalent interactions. These findings highlight the potential of this implant system for MS-related spasticity management, supporting further research into long-acting implants to improve treatment adherence and patient outcomes.

Drug Delivery and Translational ResearchVol. 15(12)
Queen's University Belfast (GB), University of Ulster (GB), Universidad de Sevilla (ES)
Universidad de Sevilla, Ministerio de Ciencia e Innovación, Engineering and Physical Sciences Research Council
Good health and well-being
Openalex Percentile: Top 9%
Advanced Drug Delivery Systems
3.16
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.