BackgroundCardiac magnetic resonance (CMR) is challenging in patients implanted with metallic devices, such as pacemakers or defibrillators, given metallic susceptibility artifacts. The technique of T1-mapping investigates interstitial fibrosis. The most used method for myocardial T1-mapping is the modified Look-Locker Inversion recovery sequence (MOLLI) using balanced steady-state free precession (SSFP). However, SSFP is susceptible to off-resonance artifacts, leading to errors. Gradient echo (GRE) sequences are less prone to these artifacts.PurposeTo investigate whether T1-mapping using GRE was comparable to SSFP in this population.Material and MethodsPre/post-contrast T1-mapping was performed on 16 devices utilizing MOLLI with SSFP and GRE strategies at 1.5 T, as well as 10 non-device controls. The difference in mean T1 time by SSFP versus GRE (both pre- and post-contrast for each slice) for device patients was analyzed.ResultsNative T1 for the device cohort was 1053 ± 94 ms for SSFP and 969 ± 83 ms for GRE. GRE T1 measurements were shorter than SSFP measurements (difference over all slices for SSFP vs. GRE pre-/post-contrast were 74 ms and 27 ms). Mean λ for GRE (devices) was 0.520 ± 0.194 (p = 0.30). λ for SSFP (devices) was 0.536 ± 0.124 (<i>P</i> = 0.08). There was no difference in λ between SSFP versus GRE in device patients (<i>P</i> = 0.91). The percentage of segments identified as artifact on T1 maps for device patients was 24% and 45% for GRE and SSFP, respectively.ConclusionCompared to SSFP, T1 values using GRE were consistently shorter, while λ values remained equivalent. There was less visual artifact on GRE images, suggesting advantageous utility over SSFP in patients with cardiac devices.

Authors

Institutions

Publication Details

Journal
Acta Radiologica
Published
2025-04-15
DOI
https://doi.org/10.1177/02841851251332461
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of GRE versus SSFP-based cardiac T1-mapping in device patients

Kevin M. Koch, Jason Rubenstein, El‐Sayed H. Ibrahim, Noelle Garster
1 links
Acta Radiologica
Advanced MRI Techniques and Applications
article

Comparison of GRE versus SSFP-based cardiac T1-mapping in device patients

Kevin M. Koch, Jason Rubenstein, El‐Sayed H. Ibrahim, Noelle Garster
article en

Abstract

BackgroundCardiac magnetic resonance (CMR) is challenging in patients implanted with metallic devices, such as pacemakers or defibrillators, given metallic susceptibility artifacts. The technique of T1-mapping investigates interstitial fibrosis. The most used method for myocardial T1-mapping is the modified Look-Locker Inversion recovery sequence (MOLLI) using balanced steady-state free precession (SSFP). However, SSFP is susceptible to off-resonance artifacts, leading to errors. Gradient echo (GRE) sequences are less prone to these artifacts.PurposeTo investigate whether T1-mapping using GRE was comparable to SSFP in this population.Material and MethodsPre/post-contrast T1-mapping was performed on 16 devices utilizing MOLLI with SSFP and GRE strategies at 1.5 T, as well as 10 non-device controls. The difference in mean T1 time by SSFP versus GRE (both pre- and post-contrast for each slice) for device patients was analyzed.ResultsNative T1 for the device cohort was 1053 ± 94 ms for SSFP and 969 ± 83 ms for GRE. GRE T1 measurements were shorter than SSFP measurements (difference over all slices for SSFP vs. GRE pre-/post-contrast were 74 ms and 27 ms). Mean λ for GRE (devices) was 0.520 ± 0.194 (p = 0.30). λ for SSFP (devices) was 0.536 ± 0.124 (<i>P</i> = 0.08). There was no difference in λ between SSFP versus GRE in device patients (<i>P</i> = 0.91). The percentage of segments identified as artifact on T1 maps for device patients was 24% and 45% for GRE and SSFP, respectively.ConclusionCompared to SSFP, T1 values using GRE were consistently shorter, while λ values remained equivalent. There was less visual artifact on GRE images, suggesting advantageous utility over SSFP in patients with cardiac devices.

Acta RadiologicaVol. 66(9)
Medical College of Wisconsin (US)
Good health and well-being
Openalex Percentile: Top 88%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Comparison of GRE versus SSFP-based cardiac T1-mapping in device patients — Kevin M. Koch, Jason Rubenstein, et al. · Acta Radiologica (2025) | TGRS Research Map | TGRS