Perfusion Parameter Map Generation from 3 Phases of Computed Tomography Perfusion in Stroke Using Generative Adversarial Networks

Computed tomography perfusion (CTP) plays a crucial role in guiding reperfusion therapy and patient selection for acute ischemic stroke (AIS) through perfusion parameter maps of the brain; however, its widespread use is limited by the complexity of acquisition protocols and high radiation dose. Previous studies have attempted to reduce radiation exposure by equally lowering the temporal sampling rate; however, it may miss the peak of arterial enhancement, leading to underestimation of blood flow parameter. Here, we investigate the feasibility of using a generative adversarial network (GAN) to generate perfusion maps from 3 phases of CTP (mCTP). The three phases were chosen based on the multiphase computed tomography angiography scanning protocol: the peak arterial input function phase, the peak venous output function phase, and the delayed venous output function phase. The findings demonstrate that the GAN model achieved high visual overlap and performance for cerebral blood flow and time-to-maximum maps, with a mean structural similarity index measure of 0.921 to 0.971 and 0.817 to 0.883, a mean normalized root mean squared error of 0.019 to 0.108 and 0.058 to 0.064, and a mean learned perceptual image patch similarity of 0.039 to 0.088 and 0.141 to 0.146, respectively. For the 2 external datasets, the volume agreement between the model- and CTP-derived infarct and hypoperfusion areas was the intraclass correlation coefficient of 0.731 to 0.883 and 0.499 to 0.635, and the Spearman correlation coefficient of 0.720 to 0.808 and 0.533 to 0.6540, respectively. Qualitative assessments of diagnostic quality further confirmed that the mCTP-derived maps were comparable to those obtained from traditional CTP. In conclusion, the GAN-based model is effective in generating perfusion maps from mCTP, which could serve as a viable alternative to traditional CTP in the diagnostic evaluation of AIS.

Authors

Institutions

Publication Details

Journal
Research
Published
2025-01-01
DOI
https://doi.org/10.34133/research.0689
Citations
3
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
4.08
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Perfusion Parameter Map Generation from 3 Phases of Computed Tomography Perfusion in Stroke Using Generative Adversarial Networks

Cuidie Zeng, Jianhua Ma, Bin Zhang, Dong Zeng et al.
3 citations
Research
Advanced MRI Techniques and Applications
4.08
article

Perfusion Parameter Map Generation from 3 Phases of Computed Tomography Perfusion in Stroke Using Generative Adversarial Networks

Cuidie Zeng, Jianhua Ma, Bin Zhang, Dong Zeng, Xiao Zhang, Xiaoling Wu, Baoliang Guo, Fusheng Ouyang
article en
3 citations

Abstract

Computed tomography perfusion (CTP) plays a crucial role in guiding reperfusion therapy and patient selection for acute ischemic stroke (AIS) through perfusion parameter maps of the brain; however, its widespread use is limited by the complexity of acquisition protocols and high radiation dose. Previous studies have attempted to reduce radiation exposure by equally lowering the temporal sampling rate; however, it may miss the peak of arterial enhancement, leading to underestimation of blood flow parameter. Here, we investigate the feasibility of using a generative adversarial network (GAN) to generate perfusion maps from 3 phases of CTP (mCTP). The three phases were chosen based on the multiphase computed tomography angiography scanning protocol: the peak arterial input function phase, the peak venous output function phase, and the delayed venous output function phase. The findings demonstrate that the GAN model achieved high visual overlap and performance for cerebral blood flow and time-to-maximum maps, with a mean structural similarity index measure of 0.921 to 0.971 and 0.817 to 0.883, a mean normalized root mean squared error of 0.019 to 0.108 and 0.058 to 0.064, and a mean learned perceptual image patch similarity of 0.039 to 0.088 and 0.141 to 0.146, respectively. For the 2 external datasets, the volume agreement between the model- and CTP-derived infarct and hypoperfusion areas was the intraclass correlation coefficient of 0.731 to 0.883 and 0.499 to 0.635, and the Spearman correlation coefficient of 0.720 to 0.808 and 0.533 to 0.6540, respectively. Qualitative assessments of diagnostic quality further confirmed that the mCTP-derived maps were comparable to those obtained from traditional CTP. In conclusion, the GAN-based model is effective in generating perfusion maps from mCTP, which could serve as a viable alternative to traditional CTP in the diagnostic evaluation of AIS.

ResearchVol. 8
Hebei Medical University (CN), The First People's Hospital of Shunde (CN), First Affiliated Hospital of Hebei Medical University (CN), First Affiliated Hospital of Jinan University (CN), Shaanxi University of Science and Technology (CN), Southern Medical University (CN), Xi'an Jiaotong University (CN)
Openalex Percentile: Top 7%
Advanced MRI Techniques and Applications
4.08
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.