Rarefied xenon flow in orificed hollow cathodes

A parametric study is conducted to quantify the effect of the keeper electrode geometry on the xenon neutral flow quantities within orificed hollow cathodes, prior to ignition. The keeper impinges directly on the flow out of the cathode orifice and its geometry influences the product between the pressure in the orifice–keeper region and the cathode-to-keeper distance. A representative cathode is simulated using the Direct Simulation Monte Carlo method. The numerical model is first validated with computational results from the literature. A parametric study is then conducted. Parameters include the cathode pressure–diameter in the range of 1–5 Torr cm and the following geometric ratios (and ranges): cathode orifice-to-inner radii (0.1–0.7), keeper orifice-to-cathode orifice radii (1–5), and keeper distance-to-cathode-orifice diameter (0.5–10). It is found that, if both keeper and cathode have identical orifice radii, the flow remains subsonic in the orifice-to-keeper region. In most cases, however, the flow becomes underexpanded and supersonic, and the static pressure within the orifice-to-keeper region is, on average, 4% that of the upstream pressure value. The orifice–keeper region pressure increases with either a decrease in the keeper orifice diameter or an increase in the distance between cathode and keeper, in agreement with literature data. Both trends are explained through conservation laws. A statistical study of numerical results reveals that the ratio of ignition-to-nominal mass flow rates has a most probable value of 50, which suggests that heaterless cathode ignition at a minimum DC voltage may be achieved by increasing the input mass flow rate by a factor of 50.

Authors

Institutions

Publication Details

Journal
Journal of Applied Physics
Published
2025-04-15
DOI
https://doi.org/10.1063/5.0249172
Citations
1
Primary Topic
Plasma Diagnostics and Applications
Type
article
Field-Weighted Citation Impact
0.73

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Rarefied xenon flow in orificed hollow cathodes

Andrei Khodak, Igor Kaganovich, Pierre-Yves Taunay, Sangeeta P. Vinoth et al.
1 citations
Journal of Applied Physics
Plasma Diagnostics and Applications
0.73
article

Rarefied xenon flow in orificed hollow cathodes

Andrei Khodak, Igor Kaganovich, Pierre-Yves Taunay, Sangeeta P. Vinoth, Willca Villafana
article en
1 citations

Abstract

A parametric study is conducted to quantify the effect of the keeper electrode geometry on the xenon neutral flow quantities within orificed hollow cathodes, prior to ignition. The keeper impinges directly on the flow out of the cathode orifice and its geometry influences the product between the pressure in the orifice–keeper region and the cathode-to-keeper distance. A representative cathode is simulated using the Direct Simulation Monte Carlo method. The numerical model is first validated with computational results from the literature. A parametric study is then conducted. Parameters include the cathode pressure–diameter in the range of 1–5 Torr cm and the following geometric ratios (and ranges): cathode orifice-to-inner radii (0.1–0.7), keeper orifice-to-cathode orifice radii (1–5), and keeper distance-to-cathode-orifice diameter (0.5–10). It is found that, if both keeper and cathode have identical orifice radii, the flow remains subsonic in the orifice-to-keeper region. In most cases, however, the flow becomes underexpanded and supersonic, and the static pressure within the orifice-to-keeper region is, on average, 4% that of the upstream pressure value. The orifice–keeper region pressure increases with either a decrease in the keeper orifice diameter or an increase in the distance between cathode and keeper, in agreement with literature data. Both trends are explained through conservation laws. A statistical study of numerical results reveals that the ratio of ignition-to-nominal mass flow rates has a most probable value of 50, which suggests that heaterless cathode ignition at a minimum DC voltage may be achieved by increasing the input mass flow rate by a factor of 50.

Journal of Applied PhysicsVol. 137(15)
United States Naval Academy (US), Princeton Plasma Physics Laboratory (US)
U.S. Department of Defense, U.S. Department of Energy, U.S. Navy, U.S. Naval Academy, Princeton Plasma Physics Laboratory
Openalex Percentile: Top 30%
Plasma Diagnostics and Applications
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.