Centrifugal Microfluidic Lateral Flow Assay Enables High Sensitivity Interleukin-6 Detection and Ultrafast Readout of Elevated Analyte Levels

Balancing sensitivity and time to result is always a challenging part of the development of analytical tools and is of particular importance in clinical and point-of-care diagnostics. In this study, a highly sensitive fluorescence interleukin-6 lateral flow assay (LFA) was developed using centrifugal microfluidics. The sample flow rate through the lateral flow membrane is determined by centrifugal force, which can be precisely controlled with a processing device. Using this precise flow control, an ultrafast early readout after 30 s with a sensitivity of 78.3 pg/mL and a quantitative measurement up to 2000 pg/mL was achieved. Afterward, the flow rate was reduced, and thus, the incubation time increased to achieve a maximum sensitivity of 1.2 pg/mL within 13 min of run time. This high-performance LFA is intended to help particularly vulnerable patient groups, such as pregnant women and neonates, where a rapid and highly sensitive diagnosis of inflammatory biomarkers can make a life-saving difference. In addition to medical applications, the presented system can also be used for the analysis of binding kinetics directly on the lateral flow strip. This enables the development of lateral flow assays with the highest possible sensitivity in the shortest time. Therefore, this advancement leads to a new era of point-of-care testing with future prospects for fully automated centrifugal cassettes with enhanced performance.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2025-04-15
DOI
https://doi.org/10.1021/acs.analchem.5c00413
Citations
2
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
1.35
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Centrifugal Microfluidic Lateral Flow Assay Enables High Sensitivity Interleukin-6 Detection and Ultrafast Readout of Elevated Analyte Levels

Roland Zengerle, Anna Klebes, Bastian J. Breiner, Susanna M. Früh et al.
2 citations
Analytical Chemistry
Biosensors and Analytical Detection
1.35
article

Centrifugal Microfluidic Lateral Flow Assay Enables High Sensitivity Interleukin-6 Detection and Ultrafast Readout of Elevated Analyte Levels

Roland Zengerle, Anna Klebes, Bastian J. Breiner, Susanna M. Früh, Daniel M. Kainz, Tobias Hutzenlaub, Nils Paust, Nadine Borst, Felix von Stetten
article en
2 citations

Abstract

Balancing sensitivity and time to result is always a challenging part of the development of analytical tools and is of particular importance in clinical and point-of-care diagnostics. In this study, a highly sensitive fluorescence interleukin-6 lateral flow assay (LFA) was developed using centrifugal microfluidics. The sample flow rate through the lateral flow membrane is determined by centrifugal force, which can be precisely controlled with a processing device. Using this precise flow control, an ultrafast early readout after 30 s with a sensitivity of 78.3 pg/mL and a quantitative measurement up to 2000 pg/mL was achieved. Afterward, the flow rate was reduced, and thus, the incubation time increased to achieve a maximum sensitivity of 1.2 pg/mL within 13 min of run time. This high-performance LFA is intended to help particularly vulnerable patient groups, such as pregnant women and neonates, where a rapid and highly sensitive diagnosis of inflammatory biomarkers can make a life-saving difference. In addition to medical applications, the presented system can also be used for the analysis of binding kinetics directly on the lateral flow strip. This enables the development of lateral flow assays with the highest possible sensitivity in the shortest time. Therefore, this advancement leads to a new era of point-of-care testing with future prospects for fully automated centrifugal cassettes with enhanced performance.

Analytical ChemistryVol. 97(16)
University of Freiburg (DE), Hahn-Schickard-Gesellschaft für angewandte Forschung (DE)
Clean water and sanitation
Openalex Percentile: Top 21%
Biosensors and Analytical Detection
1.35
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.