METHOD VALIDATION FOR COPPER DETERMINATION IN HUMAN HAIR SAMPLES THROUGH GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROMETRY

A simple, cheap, and sensitive analytical method was validated for the determination of copper in human hair after microwave digestion. Method validation parameters such as linearity, precision, accuracy, limit of detection (LOD) and limit of quantification (LOQ) were determined. A graphite furnace atomic absorption spectrophotometer has been used. The developed method was linear in the concentration range of 2 - 20 μg/L with a 0.9979 coefficient of determination. The recoveries obtained for the copper ranged from 90.46-94.96%, with a precision not exceeding 3.95% relative standard deviation (RDS%) and system suitability test with RSD% lower than 1.58%. LOD was found to be 0.05632 μg/g and LOQ 0.18745 μg/g. The analyzed samples were from healthy humans and the study shown similar concentration of copper in hairs collected from adult, teenager men and female. The proposed method was considered adequate for the determination of copper in hair samples.

Authors

Publication Details

Journal
Studia Universitatis Babeș-Bolyai Chemia
Published
2025-03-20
DOI
https://doi.org/10.24193/subbchem.2025.1.13
Primary Topic
Contact Dermatitis and Allergies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

METHOD VALIDATION FOR COPPER DETERMINATION IN HUMAN HAIR SAMPLES THROUGH GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROMETRY

Simona Dobrinaș, Alina Soceanu, Nicoleta Matei, Semaghiul Birghilă et al.
1 links
Studia Universitatis Babeș-Bolyai Chemia
Contact Dermatitis and Allergies
article

METHOD VALIDATION FOR COPPER DETERMINATION IN HUMAN HAIR SAMPLES THROUGH GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROMETRY

Simona Dobrinaș, Alina Soceanu, Nicoleta Matei, Semaghiul Birghilă, Ana-Maria Ilie, Viorica Popescu
article en

Abstract

A simple, cheap, and sensitive analytical method was validated for the determination of copper in human hair after microwave digestion. Method validation parameters such as linearity, precision, accuracy, limit of detection (LOD) and limit of quantification (LOQ) were determined. A graphite furnace atomic absorption spectrophotometer has been used. The developed method was linear in the concentration range of 2 - 20 μg/L with a 0.9979 coefficient of determination. The recoveries obtained for the copper ranged from 90.46-94.96%, with a precision not exceeding 3.95% relative standard deviation (RDS%) and system suitability test with RSD% lower than 1.58%. LOD was found to be 0.05632 μg/g and LOQ 0.18745 μg/g. The analyzed samples were from healthy humans and the study shown similar concentration of copper in hairs collected from adult, teenager men and female. The proposed method was considered adequate for the determination of copper in hair samples.

Studia Universitatis Babeș-Bolyai Chemia
Openalex Percentile: Top 85%
Contact Dermatitis and Allergies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.