An ultrasensitive D–A fluorescent probe for dual-mode uranyl detection in environmental and biological systems

Given the escalating environmental risks posed by radioactive uranium contamination, there is an urgent demand for rapid and precise assessment of uranium levels in environmental and biological matrices. In this study, an ultrasensitive donor-acceptor fluorescent probe, TPA-BH, was developed for on-site rapid detection of uranium in both environmental samples and living systems. Owing to the synergistic effects of aggregation-induced emission (AIE), twisted intramolecular charge transfer (TICT) and specific coordination reactions, the probe achieved exceptional sensing performance: an ultra-low detection limit (0.0417 ppb, 720-fold below the WHO drinking water threshold), ultra-fast response (<1 min), and large Stokes shift (140 nm) with excellent selectivity across wide pH ranges (2-10). The probe demonstrated remarkable anti-interference capability in complex matrices while maintaining low cytotoxicity, enabling its successful application in real water analysis and live-cell imaging. Systematic investigations including photophysical characterization, real sample analysis, and recognition mechanism studies confirm the probe's potential for early warning of uranium pollution and public health risk assessment.

Authors

Institutions

Publication Details

Journal
Analytical Methods
Published
2025-01-01
DOI
https://doi.org/10.1039/d5ay00379b
Citations
2
Primary Topic
Radioactive element chemistry and processing
Type
article
Field-Weighted Citation Impact
1.07
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An ultrasensitive D–A fluorescent probe for dual-mode uranyl detection in environmental and biological systems

Yuliang Xiao, Meirong Su, Fang Yang, Diyun Chen et al.
2 citations
Analytical Methods
Radioactive element chemistry and processing
1.07
article

An ultrasensitive D–A fluorescent probe for dual-mode uranyl detection in environmental and biological systems

Yuliang Xiao, Meirong Su, Fang Yang, Diyun Chen, Jie Xu, Hui Sun, Shen-neng Wang, Yaojin Wang, Zhen-ni Yi
article en
2 citations

Abstract

Given the escalating environmental risks posed by radioactive uranium contamination, there is an urgent demand for rapid and precise assessment of uranium levels in environmental and biological matrices. In this study, an ultrasensitive donor-acceptor fluorescent probe, TPA-BH, was developed for on-site rapid detection of uranium in both environmental samples and living systems. Owing to the synergistic effects of aggregation-induced emission (AIE), twisted intramolecular charge transfer (TICT) and specific coordination reactions, the probe achieved exceptional sensing performance: an ultra-low detection limit (0.0417 ppb, 720-fold below the WHO drinking water threshold), ultra-fast response (<1 min), and large Stokes shift (140 nm) with excellent selectivity across wide pH ranges (2-10). The probe demonstrated remarkable anti-interference capability in complex matrices while maintaining low cytotoxicity, enabling its successful application in real water analysis and live-cell imaging. Systematic investigations including photophysical characterization, real sample analysis, and recognition mechanism studies confirm the probe's potential for early warning of uranium pollution and public health risk assessment.

Analytical MethodsVol. 17(18)
Guangzhou University (CN), Pearl River Hydraulic Research Institute (CN)
Openalex Percentile: Top 25%
Radioactive element chemistry and processing
1.07
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.