Novel Amperometric Sensor Based on Glassy Graphene for Flow Injection Analysis

Flow injection analysis (FIA) is widely used in drug screening, neurotransmitter detection, and water analysis. In this study, we investigated the electrochemical sensing performance of glassy graphene electrodes derived from pyrolyzed positive photoresist films (PPFs) via rapid thermal annealing (RTA) on SiO<sub>2</sub>/Si and polycrystalline diamond (PCD). Glassy graphene films fabricated at 800, 900, and 950 °C were characterized using Raman spectroscopy, scanning electron microscopy (SEM), and atomic force microscopy (AFM) to assess their structural and morphological properties. Electrochemical characterization in phosphate-buffered saline (PBS, pH 7.4) revealed that annealing temperature and substrate type influence the potential window and double-layer capacitance. The voltammetric response of glassy graphene electrodes was further evaluated using the surface-insensitive [Ru(NH<sub>3</sub>)<sub>6</sub>]<sup>3+/2+</sup> redox marker, the surface-sensitive [Fe(CN)<sub>6</sub>]<sup>3-/4-</sup> redox couple, and adrenaline, demonstrating that electron transfer efficiency is governed by annealing temperature and substrate-induced microstructural changes. FIA with amperometric detection showed a linear electrochemical response to adrenaline in the 3-300 µM range, achieving a low detection limit of 1.05 µM and a high sensitivity of 1.02 µA cm<sup>-2</sup>/µM. These findings highlight the potential of glassy graphene as a cost-effective alternative for advanced electrochemical sensors, particularly in biomolecule detection and analytical applications.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2025-04-13
DOI
https://doi.org/10.3390/s25082454
Citations
6
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
4.38
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Novel Amperometric Sensor Based on Glassy Graphene for Flow Injection Analysis

A. Pasquarelli, Dietmar Kissinger, Ramtin E. Shabgahi, Alexander Minkow et al.
6 citations
Sensors
Electrochemical sensors and biosensors
4.38
article

Novel Amperometric Sensor Based on Glassy Graphene for Flow Injection Analysis

A. Pasquarelli, Dietmar Kissinger, Ramtin E. Shabgahi, Alexander Minkow, Michael Wild
article en
6 citations

Abstract

Flow injection analysis (FIA) is widely used in drug screening, neurotransmitter detection, and water analysis. In this study, we investigated the electrochemical sensing performance of glassy graphene electrodes derived from pyrolyzed positive photoresist films (PPFs) via rapid thermal annealing (RTA) on SiO<sub>2</sub>/Si and polycrystalline diamond (PCD). Glassy graphene films fabricated at 800, 900, and 950 °C were characterized using Raman spectroscopy, scanning electron microscopy (SEM), and atomic force microscopy (AFM) to assess their structural and morphological properties. Electrochemical characterization in phosphate-buffered saline (PBS, pH 7.4) revealed that annealing temperature and substrate type influence the potential window and double-layer capacitance. The voltammetric response of glassy graphene electrodes was further evaluated using the surface-insensitive [Ru(NH<sub>3</sub>)<sub>6</sub>]<sup>3+/2+</sup> redox marker, the surface-sensitive [Fe(CN)<sub>6</sub>]<sup>3-/4-</sup> redox couple, and adrenaline, demonstrating that electron transfer efficiency is governed by annealing temperature and substrate-induced microstructural changes. FIA with amperometric detection showed a linear electrochemical response to adrenaline in the 3-300 µM range, achieving a low detection limit of 1.05 µM and a high sensitivity of 1.02 µA cm<sup>-2</sup>/µM. These findings highlight the potential of glassy graphene as a cost-effective alternative for advanced electrochemical sensors, particularly in biomolecule detection and analytical applications.

SensorsVol. 25(8)
Universität Ulm (DE), Center for Integrated Quantum Science and Technology (DE), Diamond Materials (Germany) (DE)
Clean water and sanitation
Openalex Percentile: Top 6%
Electrochemical sensors and biosensors
4.38
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.