Extending the Traceability of Dynamic Calibration to the High-Pressure Regime Using a Shock Tube

In this paper, a development of the shock tube at RISE, the National Metrology Institute of Sweden, to extend its capability to the high-pressure regime is presented. The shock tube was developed to be operated in three different configurations: conventional, with an amplification system and with a converging cone. In the conventional and with the amplification system, the well-established shock tube analytical solution was used to calculate the reference pressure, while in the converging cone, a numerical simulation was applied. To demonstrate the capabilities and limitations of each configuration, a device under test (DUT) was characterized. The results show a good agreement in the DUT dynamic response calculated using the three configurations in the overlap regions between them. The uncertainty in measurements was estimated for each configuration. The three configurations complement each other to reach a pressure range from 0.1 MPa to 25 MPa and a frequency range from 0.5 kHz to 500 kHz.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2025-04-13
DOI
https://doi.org/10.3390/s25082453
Citations
1
Primary Topic
Scientific Measurement and Uncertainty Evaluation
Type
article
Field-Weighted Citation Impact
1.40

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Extending the Traceability of Dynamic Calibration to the High-Pressure Regime Using a Shock Tube

Fredrik Arrhén, Olle Penttinen, G. Jönsson, Eynas Amer
1 citations
Sensors
Scientific Measurement and Uncertainty Evaluation
1.40
article

Extending the Traceability of Dynamic Calibration to the High-Pressure Regime Using a Shock Tube

Fredrik Arrhén, Olle Penttinen, G. Jönsson, Eynas Amer
article en
1 citations

Abstract

In this paper, a development of the shock tube at RISE, the National Metrology Institute of Sweden, to extend its capability to the high-pressure regime is presented. The shock tube was developed to be operated in three different configurations: conventional, with an amplification system and with a converging cone. In the conventional and with the amplification system, the well-established shock tube analytical solution was used to calculate the reference pressure, while in the converging cone, a numerical simulation was applied. To demonstrate the capabilities and limitations of each configuration, a device under test (DUT) was characterized. The results show a good agreement in the DUT dynamic response calculated using the three configurations in the overlap regions between them. The uncertainty in measurements was estimated for each configuration. The three configurations complement each other to reach a pressure range from 0.1 MPa to 25 MPa and a frequency range from 0.5 kHz to 500 kHz.

SensorsVol. 25(8)
RISE Research Institutes of Sweden (SE)
VINNOVA
Openalex Percentile: Top 17%
Scientific Measurement and Uncertainty Evaluation
1.40
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Extending the Traceability of Dynamic Calibration to the High-Pressure Regime Using a Shock Tube — Fredrik Arrhén, Olle Penttinen, et al. · Sensors (2025) | TGRS Research Map | TGRS