A Photochemical Vapor Generation Method for the Determination of Hg and Pb in Imitation Jewelry by Inductively Coupled Plasma Optical Emission Spectrometry

The monitoring of contaminants in imitation jewelry has become important nowadays due to the high amount of products sold worldwide. Due to the complexity of the sample matrix (composed mainly of metals in high concentration), sample analysis can be very challenging. One interesting alternative for this purpose is the use of photochemical vapor generation coupled to inductively coupled plasma optical emission spectrometry (PVG-ICP-OES) due to the ability of separating the analytes from the sample solution prior to analysis; additionally, it is considered an eco-friendly approach if compared to other vapor generation techniques. Thus, this work presents the development and application of a PVG-ICP-OES system for the determination of Hg and Pb in imitation jewelry after sample dissolution in hydrochloric acid. The PVG system was built with two UV lamps (254 nm), a quartz capillary reactor, and a glass gas-liquid separator. Acetic acid concentration and UV exposure time were optimized using a central composite design, as well as the carrier gas flow rate and the radiofrequency (RF) power for the ICP-OES. The optimum conditions were achieved at 30% v/v acetic acid, 60 s reaction time, 0.035 L min−1 carrier gas flow rate, and 1310 W for RF power. The influence of the sample matrix and chemical modifiers were studied, where it was found that the presence of the sample matrix may cause suppression of the analytical signal. The accuracy of the method was evaluated by recovery tests, which ranged from 88 to 102%. The detection limits ranged from 1 to 3 mg g−1, allowing the monitoring of Hg and Pb in imitation jewelry.

Authors

Institutions

Publication Details

Journal
Chemosensors
Published
2025-04-14
DOI
https://doi.org/10.3390/chemosensors13040144
Citations
2
Primary Topic
Mercury impact and mitigation studies
Type
article
Field-Weighted Citation Impact
2.40

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Photochemical Vapor Generation Method for the Determination of Hg and Pb in Imitation Jewelry by Inductively Coupled Plasma Optical Emission Spectrometry

Fabrício Braga, Jefferson Santos de Gois
2 citations
Chemosensors
Mercury impact and mitigation studies
2.40
article

A Photochemical Vapor Generation Method for the Determination of Hg and Pb in Imitation Jewelry by Inductively Coupled Plasma Optical Emission Spectrometry

Fabrício Braga, Jefferson Santos de Gois
article en
2 citations

Abstract

The monitoring of contaminants in imitation jewelry has become important nowadays due to the high amount of products sold worldwide. Due to the complexity of the sample matrix (composed mainly of metals in high concentration), sample analysis can be very challenging. One interesting alternative for this purpose is the use of photochemical vapor generation coupled to inductively coupled plasma optical emission spectrometry (PVG-ICP-OES) due to the ability of separating the analytes from the sample solution prior to analysis; additionally, it is considered an eco-friendly approach if compared to other vapor generation techniques. Thus, this work presents the development and application of a PVG-ICP-OES system for the determination of Hg and Pb in imitation jewelry after sample dissolution in hydrochloric acid. The PVG system was built with two UV lamps (254 nm), a quartz capillary reactor, and a glass gas-liquid separator. Acetic acid concentration and UV exposure time were optimized using a central composite design, as well as the carrier gas flow rate and the radiofrequency (RF) power for the ICP-OES. The optimum conditions were achieved at 30% v/v acetic acid, 60 s reaction time, 0.035 L min−1 carrier gas flow rate, and 1310 W for RF power. The influence of the sample matrix and chemical modifiers were studied, where it was found that the presence of the sample matrix may cause suppression of the analytical signal. The accuracy of the method was evaluated by recovery tests, which ranged from 88 to 102%. The detection limits ranged from 1 to 3 mg g−1, allowing the monitoring of Hg and Pb in imitation jewelry.

ChemosensorsVol. 13(4)
Universidade do Estado do Rio de Janeiro (BR)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior, Conselho Nacional de Desenvolvimento Científico e Tecnológico, Universidade do Estado do Rio de Janeiro
Openalex Percentile: Top 13%
Mercury impact and mitigation studies
2.40
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.