Performance Assessment and Heat Transfer Coefficient of Antifreeze Fluids in Low-Temperature Solar Collectors

This study conducts a comparative performance analysis of three different low-temperature solar collector systems: flat plate solar collectors (FPCs), heat pipe evacuated tube solar collectors (HPETCs), and heat pipe flat plate solar collectors (HPFPCs). Key performance parameters, such as heat transfer coefficients, useful heat, and thermal efficiency, are analyzed under varying mass flow rate, fluid temperature, and antifreeze concentration. The objective is to evaluate the thermal performance of these systems using different heat transfer fluids, specifically water, and mixtures of 30% and 50% ethylene glycol and propylene glycol. The performance data indicate that the heat transfer coefficient in the HPFPC diminishes by 28% and 41% when antifreeze is employed at concentrations of 30% and 50%, respectively. Furthermore, the integration of heat pipes with water in a flat plate solar collector results in efficiency enhancements, with respect to FPCs, of up to 13% at a fluid temperature of 30 °C, and up to 21% at 80 °C. At the elevated fluid temperature of 80 °C, an efficiency increase of 13% is observed with a 30% ethylene glycol concentration. The incorporation of heat pipes leads to an efficiency improvement of up to 6.5% in comparison to traditional flat plate solar collectors. This study highlights the significant impact of fluid properties, affecting the convective heat transfer coefficient, on the overall efficiency of solar collectors, emphasizing the importance of optimizing fluid composition and operating conditions for enhanced thermal performance.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2025-04-14
DOI
https://doi.org/10.3390/app15084323
Primary Topic
Solar Thermal and Photovoltaic Systems
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance Assessment and Heat Transfer Coefficient of Antifreeze Fluids in Low-Temperature Solar Collectors

Orlando Guarneros García, J. Bedolla-Hernández, Ricardo Balcázar, Rubén Mil‐Martínez et al.
Applied Sciences
Solar Thermal and Photovoltaic Systems
article

Performance Assessment and Heat Transfer Coefficient of Antifreeze Fluids in Low-Temperature Solar Collectors

Orlando Guarneros García, J. Bedolla-Hernández, Ricardo Balcázar, Rubén Mil‐Martínez, Guerlin Romage, José Michael Cruz, Jorge E. De León-Ruiz, Alejandro Zacarías, G. Gutiérrez-Urueta, Simón E. Carranco
article en

Abstract

This study conducts a comparative performance analysis of three different low-temperature solar collector systems: flat plate solar collectors (FPCs), heat pipe evacuated tube solar collectors (HPETCs), and heat pipe flat plate solar collectors (HPFPCs). Key performance parameters, such as heat transfer coefficients, useful heat, and thermal efficiency, are analyzed under varying mass flow rate, fluid temperature, and antifreeze concentration. The objective is to evaluate the thermal performance of these systems using different heat transfer fluids, specifically water, and mixtures of 30% and 50% ethylene glycol and propylene glycol. The performance data indicate that the heat transfer coefficient in the HPFPC diminishes by 28% and 41% when antifreeze is employed at concentrations of 30% and 50%, respectively. Furthermore, the integration of heat pipes with water in a flat plate solar collector results in efficiency enhancements, with respect to FPCs, of up to 13% at a fluid temperature of 30 °C, and up to 21% at 80 °C. At the elevated fluid temperature of 80 °C, an efficiency increase of 13% is observed with a 30% ethylene glycol concentration. The incorporation of heat pipes leads to an efficiency improvement of up to 6.5% in comparison to traditional flat plate solar collectors. This study highlights the significant impact of fluid properties, affecting the convective heat transfer coefficient, on the overall efficiency of solar collectors, emphasizing the importance of optimizing fluid composition and operating conditions for enhanced thermal performance.

Applied SciencesVol. 15(8)
Universidad Autónoma de Tlaxcala (MX), Autonomous University of San Luis Potosí (MX), Tecnológico Nacional de México (MX), Instituto Tecnológico de Apizaco (MX), Centro de Investigación en Materiales Avanzados (MX), Universidad del Ejército y Fuerza Aérea (MX), Tecnológico de Estudios Superiores de Coacalco, Instituto Politécnico Nacional (MX)
Instituto Politécnico Nacional, Consejo Nacional de Ciencia y Tecnología
Openalex Percentile: Top 95%
Solar Thermal and Photovoltaic Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.