Calibration-free, high-sensitivity CO2 sensor based on cavity ringdown spectroscopy for real-time seed respiration monitoring

A real-time, calibration-free, and high-sensitively CO2 sensor based on cavity ringdown spectroscopy (CRDS) has been developed, incorporating a Fabry-Pérot (F-P) cavity with a finesse of 6500 and an STM32-controlled ringdown acquisition scheme. The sensor enables CO2 concentration measurements at the ppb level. Allan variance analysis indicates a minimum detectable sensitivity of 1.452 × 10-9 cm-1 at an integration time of 452 s, corresponding to the minimum detectable gas concentration of 400 ppb, which demonstrates the sensor's long-term stability. In addition, using this sensor, the effects of different soaking durations on rice seed respiration were investigated. The results indicate that the sensor can effectively monitor and differentiate the respiration intensity and rate of seeds under varying soaking times, allowing real-time observation of seed respiration status.

Authors

Institutions

Publication Details

Journal
Review of Scientific Instruments
Published
2025-04-01
DOI
https://doi.org/10.1063/5.0248875
Primary Topic
Spectroscopy and Laser Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Calibration-free, high-sensitivity CO2 sensor based on cavity ringdown spectroscopy for real-time seed respiration monitoring

Guqing Guo, Chuanliang Li, Yueting Zhou, Haokai Li et al.
Review of Scientific Instruments
Spectroscopy and Laser Applications
article

Calibration-free, high-sensitivity CO2 sensor based on cavity ringdown spectroscopy for real-time seed respiration monitoring

Guqing Guo, Chuanliang Li, Yueting Zhou, Haokai Li, Xiaocong Sun, Yali Tian, Kangjie Yuan, Ting Gong, Xuanbing Qiu
article en

Abstract

A real-time, calibration-free, and high-sensitively CO2 sensor based on cavity ringdown spectroscopy (CRDS) has been developed, incorporating a Fabry-Pérot (F-P) cavity with a finesse of 6500 and an STM32-controlled ringdown acquisition scheme. The sensor enables CO2 concentration measurements at the ppb level. Allan variance analysis indicates a minimum detectable sensitivity of 1.452 × 10-9 cm-1 at an integration time of 452 s, corresponding to the minimum detectable gas concentration of 400 ppb, which demonstrates the sensor's long-term stability. In addition, using this sensor, the effects of different soaking durations on rice seed respiration were investigated. The results indicate that the sensor can effectively monitor and differentiate the respiration intensity and rate of seeds under varying soaking times, allowing real-time observation of seed respiration status.

Review of Scientific InstrumentsVol. 96(4)
Shanxi University (CN), State Key Laboratory of Quantum Optics and Quantum Optics Devices, Taiyuan University of Science and Technology (CN)
National Natural Science Foundation of China, National Key Research and Development Program of China
Openalex Percentile: Top 93%
Spectroscopy and Laser Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.