Heartmate 3 left ventricular assist device system in patients with glucose-6-phosphate dehydrogenase deficiency

BackgroundGlucose-6-phosphate dehydrogenase (G6PD) deficiency is a genetic enzymatic disorder that affects millions of people worldwide and characterized by hemolysis under oxidative stress. Left ventricular assist devices (LVADs) have substantially enhanced survival and quality of life for individuals with advanced heart failure. However, their use is associated with the risk of hemolysis, thrombosis, and embolic events. These risks may be heightened in patients with glucose-6-phosphate dehydrogenase (G6PD) deficiency. Given the limited published research on this subject, the primary objective of this study was to assess the degree of hemolysis and identify associated factors in adult patients with glucose-6-phosphate dehydrogenase (G6PD) deficiency who underwent Heartmate 3 (HM3) left ventricular assist device (LVAD) implantation.MethodsThis retrospective, observational, single-center study was conducted on adult (>18 years of age) patients with G6PD deficiency, who underwent LVAD implantation using the HM3 LVAD between 2017 and 2022. Hemolysis-related investigation and findings as well as in-hospital outcome were assessed.ResultsLeft ventricular assist devices (LVADs) were successfully implanted in five adult patients with G6PD deficiency, including one individual with associated sickle cell trait (SCT). There were no major complications or fatalities during the hospitalization period. The average follow-up duration was 30 months (mean 30.4 ± 13). During the follow-up period, two patients died, two LVADs were explanted, and one patient received a heart transplant. No instances of macroscopic hemolysis were observed throughout the follow-up period.ConclusionsWhile our study was limited in size, LVADs seem safe for G6PD-deficient patients and offer significant clinical benefits. Larger studies are needed to confirm this and assess long-term interactions.

Authors

Institutions

Publication Details

Journal
Perfusion
Published
2025-04-14
DOI
https://doi.org/10.1177/02676591251334897
Primary Topic
Mechanical Circulatory Support Devices
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Heartmate 3 left ventricular assist device system in patients with glucose-6-phosphate dehydrogenase deficiency

Roberto Lorusso, Mohamad Ibrahem Abdelhamed, Elena Grasso, Ömer Ali Sayın et al.
Perfusion
Mechanical Circulatory Support Devices
article

Heartmate 3 left ventricular assist device system in patients with glucose-6-phosphate dehydrogenase deficiency

Roberto Lorusso, Mohamad Ibrahem Abdelhamed, Elena Grasso, Ömer Ali Sayın, Hassane Abdallah, Ahmed Ibrahim
article en

Abstract

BackgroundGlucose-6-phosphate dehydrogenase (G6PD) deficiency is a genetic enzymatic disorder that affects millions of people worldwide and characterized by hemolysis under oxidative stress. Left ventricular assist devices (LVADs) have substantially enhanced survival and quality of life for individuals with advanced heart failure. However, their use is associated with the risk of hemolysis, thrombosis, and embolic events. These risks may be heightened in patients with glucose-6-phosphate dehydrogenase (G6PD) deficiency. Given the limited published research on this subject, the primary objective of this study was to assess the degree of hemolysis and identify associated factors in adult patients with glucose-6-phosphate dehydrogenase (G6PD) deficiency who underwent Heartmate 3 (HM3) left ventricular assist device (LVAD) implantation.MethodsThis retrospective, observational, single-center study was conducted on adult (>18 years of age) patients with G6PD deficiency, who underwent LVAD implantation using the HM3 LVAD between 2017 and 2022. Hemolysis-related investigation and findings as well as in-hospital outcome were assessed.ResultsLeft ventricular assist devices (LVADs) were successfully implanted in five adult patients with G6PD deficiency, including one individual with associated sickle cell trait (SCT). There were no major complications or fatalities during the hospitalization period. The average follow-up duration was 30 months (mean 30.4 ± 13). During the follow-up period, two patients died, two LVADs were explanted, and one patient received a heart transplant. No instances of macroscopic hemolysis were observed throughout the follow-up period.ConclusionsWhile our study was limited in size, LVADs seem safe for G6PD-deficient patients and offer significant clinical benefits. Larger studies are needed to confirm this and assess long-term interactions.

PerfusionVol. 40(8)
Prince Sultan University (SA), Maastricht University Medical Centre (NL), Cardiovascular Institute Hospital (JP), Maastricht University (NL), Kantonsspital Baden (CH), Kantonsspital Aarau (CH)
Good health and well-being
Openalex Percentile: Top 93%
Mechanical Circulatory Support Devices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.