Imprinted materials induced by glow discharge electrolysis plasma for microcystin determination

In this work, a novel green approach for synthesizing molecularly imprinted polymers (MIPs) for determination of microcystins (MCs) was established using N-carbobenzoxy- d -glutamic acid as virtual template and glow discharge plasma instead of the conventional chemical initiator. The results showed that under the conditions of glow discharge voltage of 660 V and discharge time of 20 min, the adsorption performance (Q max = 146.4 μg g −1 , K L = 19.13 mL μg −1 ) of MIPs prepared by glow discharge electrolytic plasma-initiated polymerization was superior to that of MIPs prepared by chemical initiators. The solid-phase extraction column self-made with the obtained MIPs has a better extraction effect for MCs than that of C18 column. Furthermore, a new method for the determination of microcystin-LR (MC-LR), microcystin-RR (MC-RR) and microcystin-LY (MC-LY) by molecularly imprinted solid-phase extraction (SPE) coupled with high performance liquid chromatography (HPLC) was proposed with detection limits of 0.0313 μg L −1 , 0.318 μg L −1 and 0.675 μg L −1 , respectively, which were nearly two orders of magnitude lower than the control standard of MC-LR (1.0 μg L −1 ) in China's surface water environmental quality standards. Therefore, the analytical method proposed had good application prospects in MCs detection and water quality evaluation. Preparation of microcystin imprinted polymer using glow discharge electrolytic plasma induced polymerization. Using the prepared imprinted polymer, a SPE column was self-made to separate and purify MCs from water samples, and the MCs were determined by HPLC. • MIPs for the determination of MCs were synthesized, using N-carbobenzoxy- d -glutamic acid as pseudotemplate, using the glow discharge plasma in place of the conventional chemical initiator. • The adsorption performance of MIPs prepared by the glow discharge plasma was superior to MIPs prepared by chemical initiators. • A molecular imprinting SPE–HPLC method with high sensitivity, good selectivity and high accuracy was established for the determination of MCs in water. • MC-imprinted polymer prepared via glow discharge plasma polymerization enabled SPE-HPLC detection of MCs in water.

Authors

Institutions

Publication Details

Journal
Materials Today Chemistry
Published
2025-04-01
DOI
https://doi.org/10.1016/j.mtchem.2025.102691
Primary Topic
Marine Toxins and Detection Methods
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Imprinted materials induced by glow discharge electrolysis plasma for microcystin determination

Qiang Zhao, Guohua Jia, Guizhen Li, Jiale Xu et al.
1 links
Materials Today Chemistry
Marine Toxins and Detection Methods
article

Imprinted materials induced by glow discharge electrolysis plasma for microcystin determination

Qiang Zhao, Guohua Jia, Guizhen Li, Jiale Xu, Zaishan Wei, Min-Hyeok Yang, Yaping Wang, Jie Lü, Junxia Gao, Tao Lin, Xueping Hu, Xingliang Song, Aixiang Wang, Fengxia Pei
article en

Abstract

In this work, a novel green approach for synthesizing molecularly imprinted polymers (MIPs) for determination of microcystins (MCs) was established using N-carbobenzoxy- d -glutamic acid as virtual template and glow discharge plasma instead of the conventional chemical initiator. The results showed that under the conditions of glow discharge voltage of 660 V and discharge time of 20 min, the adsorption performance (Q max = 146.4 μg g −1 , K L = 19.13 mL μg −1 ) of MIPs prepared by glow discharge electrolytic plasma-initiated polymerization was superior to that of MIPs prepared by chemical initiators. The solid-phase extraction column self-made with the obtained MIPs has a better extraction effect for MCs than that of C18 column. Furthermore, a new method for the determination of microcystin-LR (MC-LR), microcystin-RR (MC-RR) and microcystin-LY (MC-LY) by molecularly imprinted solid-phase extraction (SPE) coupled with high performance liquid chromatography (HPLC) was proposed with detection limits of 0.0313 μg L −1 , 0.318 μg L −1 and 0.675 μg L −1 , respectively, which were nearly two orders of magnitude lower than the control standard of MC-LR (1.0 μg L −1 ) in China's surface water environmental quality standards. Therefore, the analytical method proposed had good application prospects in MCs detection and water quality evaluation. Preparation of microcystin imprinted polymer using glow discharge electrolytic plasma induced polymerization. Using the prepared imprinted polymer, a SPE column was self-made to separate and purify MCs from water samples, and the MCs were determined by HPLC. • MIPs for the determination of MCs were synthesized, using N-carbobenzoxy- d -glutamic acid as pseudotemplate, using the glow discharge plasma in place of the conventional chemical initiator. • The adsorption performance of MIPs prepared by the glow discharge plasma was superior to MIPs prepared by chemical initiators. • A molecular imprinting SPE–HPLC method with high sensitivity, good selectivity and high accuracy was established for the determination of MCs in water. • MC-imprinted polymer prepared via glow discharge plasma polymerization enabled SPE-HPLC detection of MCs in water.

Materials Today ChemistryVol. 45
Linyi University (CN), Curtin University (AU), Jining University (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 92%
Marine Toxins and Detection Methods
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.