A fracture failure criterion for concrete-concrete interface under mixed mode loading condition

Various important concrete structures are susceptible to imperfections, such as the presence of an interface.In some cases, the formation of an interface is an inevitable flaw, such as in the case of repair, dams and pre-cast concrete structures.These flaws can act as a weak link and could be responsible for the failure of the structures.One of the most widely used nondestructive techniques to monitor such damages in structures in real time is the acoustic emission (AE) technique.In this study, experimental tests are conducted on concrete-concrete interface specimens under four-point shear tests with different interface positions.The interfaces are formed between four different strengths of concrete on each side.The AE technique is used to monitor the crack growth.Based on the experimental results, A fracture criterion has been suggested based on simplified calculation of mode mixity ratio.Three different failure patterns have been identified depending on the mode mixity ratio, where cracks eventually kinked into the substrate material at a critical value of the mode mixity ratio.

Authors

Institutions

Publication Details

Published
2025-04-14
DOI
https://doi.org/10.21012/fc12.1350
Primary Topic
Structural Response to Dynamic Loads
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A fracture failure criterion for concrete-concrete interface under mixed mode loading condition

Zeeshan Abbas, Khatoon M. Pervaiz Fathima
Structural Response to Dynamic Loads
article

A fracture failure criterion for concrete-concrete interface under mixed mode loading condition

Zeeshan Abbas, Khatoon M. Pervaiz Fathima
article en

Abstract

Various important concrete structures are susceptible to imperfections, such as the presence of an interface.In some cases, the formation of an interface is an inevitable flaw, such as in the case of repair, dams and pre-cast concrete structures.These flaws can act as a weak link and could be responsible for the failure of the structures.One of the most widely used nondestructive techniques to monitor such damages in structures in real time is the acoustic emission (AE) technique.In this study, experimental tests are conducted on concrete-concrete interface specimens under four-point shear tests with different interface positions.The interfaces are formed between four different strengths of concrete on each side.The AE technique is used to monitor the crack growth.Based on the experimental results, A fracture criterion has been suggested based on simplified calculation of mode mixity ratio.Three different failure patterns have been identified depending on the mode mixity ratio, where cracks eventually kinked into the substrate material at a critical value of the mode mixity ratio.

Indian Institute of Technology Jammu (IN)
Department of Science and Technology, Ministry of Science and Technology, India, Science and Engineering Research Board
Sustainable cities and communities
Openalex Percentile: Top 92%
Structural Response to Dynamic Loads
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.