Accurate forensic identification of asphyxial deaths: Differentiating strangulation and drowning using ATR-FTIR spectroscopy

Asphyxial death is a leading cause of violent death, strangulation is more frequently seen in murder and domestic abuse cases, while drowning is one of the most common causes of accidental death. Therefore, studies on these two causes of death are beneficial to ensuring the administration of justice and increasing detection rate of criminal cases. This study investigated the viability of ATR-FTIR spectroscopy as a method for distinguishing between strangulation and drowning in autolysis and putrefaction cadavers of forensic cases. Utilizing C57BL/6 mice death models, lung tissue samples were analyzed post-mortem using ATR-FTIR spectroscopy, alongside traditional histological methods such as Hematoxylin and Eosin (HE) staining. Principal Component Analysis (PCA) and Partial Least Squares Discriminant Analysis (PLSDA) were employed to enhance the spectral data interpretation, demonstrating high accuracy in distinguishing between the two causes of death. The PLSDA model showed a 100 % accuracy in external validations for strangulation and drowning cause of death identification, highlighting the potential of ATR-FTIR spectroscopy combined with machine learning algorithms in forensic applications. The results revealed distinct biochemical signatures for strangulation and drowning, with significant changes observed in the spectral peaks associated with Amide band, protein secondary structures and nucleic acids. The integration of ATR-FTIR spectroscopy provides a non-destructive, rapid, and reliable method for forensic investigators, especially when traditional autopsy results are inconclusive due to autolysis and putrefaction. The study emphasizes how crucial it is to combine ATR-FTIR spectroscopic with histopathological examination and chemometrics to increase the precision and dependability of forensic investigations and support the administration of justice.

Authors

Institutions

Publication Details

Journal
Science & Justice
Published
2025-04-14
DOI
https://doi.org/10.1016/j.scijus.2025.101257
Citations
4
Primary Topic
Spectroscopy Techniques in Biomedical and Chemical Research
Type
article
Field-Weighted Citation Impact
6.54
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Accurate forensic identification of asphyxial deaths: Differentiating strangulation and drowning using ATR-FTIR spectroscopy

Ruina Liu, Xinggong Liang, Gongji Wang, Run Chen et al.
4 citations
Science & Justice
Spectroscopy Techniques in Biomedical and Chemical Research
6.54
article

Accurate forensic identification of asphyxial deaths: Differentiating strangulation and drowning using ATR-FTIR spectroscopy

Ruina Liu, Xinggong Liang, Gongji Wang, Run Chen, Kai Zhang, Hao Wu, Chen Shen, Shuo Wu, Mingyan Deng, Zhenyuan Wang
article en
4 citations

Abstract

Asphyxial death is a leading cause of violent death, strangulation is more frequently seen in murder and domestic abuse cases, while drowning is one of the most common causes of accidental death. Therefore, studies on these two causes of death are beneficial to ensuring the administration of justice and increasing detection rate of criminal cases. This study investigated the viability of ATR-FTIR spectroscopy as a method for distinguishing between strangulation and drowning in autolysis and putrefaction cadavers of forensic cases. Utilizing C57BL/6 mice death models, lung tissue samples were analyzed post-mortem using ATR-FTIR spectroscopy, alongside traditional histological methods such as Hematoxylin and Eosin (HE) staining. Principal Component Analysis (PCA) and Partial Least Squares Discriminant Analysis (PLSDA) were employed to enhance the spectral data interpretation, demonstrating high accuracy in distinguishing between the two causes of death. The PLSDA model showed a 100 % accuracy in external validations for strangulation and drowning cause of death identification, highlighting the potential of ATR-FTIR spectroscopy combined with machine learning algorithms in forensic applications. The results revealed distinct biochemical signatures for strangulation and drowning, with significant changes observed in the spectral peaks associated with Amide band, protein secondary structures and nucleic acids. The integration of ATR-FTIR spectroscopy provides a non-destructive, rapid, and reliable method for forensic investigators, especially when traditional autopsy results are inconclusive due to autolysis and putrefaction. The study emphasizes how crucial it is to combine ATR-FTIR spectroscopic with histopathological examination and chemometrics to increase the precision and dependability of forensic investigations and support the administration of justice.

Science & JusticeVol. 65(3)
First Affiliated Hospital of Xi'an Jiaotong University (CN), Xi'an Jiaotong University (CN)
Openalex Percentile: Top 4%
Spectroscopy Techniques in Biomedical and Chemical Research
6.54
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.