Structural of Pedicle Screw on Biomechanical Characteristics of Spinal Scoliosis Correction Deformation

Scoliosis correction methods often involve orthopedic procedures such as implant placement to stabilize movement and correct spinal deformity. The choice of surgical method is highly dependent on the location and nature of the fracture. Fractures with significant damage require a different approach compared to cases of minor injuries. Three dimensional finite element model of C1–L6 spine was used to simulate conditions with single cylindrical implant fixation under a vertical downward loading force 50 N and cylindrical screw types made of titanium alloy. The human spine, encompassing the cervical, thoracic, and lumbar regions, exhibits a complex biomechanical response when subjected to physiological loads. Displacement that occurs due to axial force can be the result of pedicle screw movement with vertebrae of the spine. Installation of 4 (four) rows of pedicle screws reduces the release of pedicle screws from the spine. The use of more fixation can reduce the stress distribution on the vertebrae of the spine.

Authors

Institutions

Publication Details

Journal
Journal of Ocean Mechanical and Aerospace -science and engineering- (JOMAse)
Published
2025-03-30
DOI
https://doi.org/10.36842/jomase.v69i1.529
Primary Topic
Medical Imaging and Analysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Structural of Pedicle Screw on Biomechanical Characteristics of Spinal Scoliosis Correction Deformation

Meifal Rusli, Weriono Weriono, Roni Eka Sahputra, Hendery Dahlan
Journal of Ocean Mechanical and Aerospace -science and engineering- (JOMAse)
Medical Imaging and Analysis
article

Structural of Pedicle Screw on Biomechanical Characteristics of Spinal Scoliosis Correction Deformation

Meifal Rusli, Weriono Weriono, Roni Eka Sahputra, Hendery Dahlan
article en

Abstract

Scoliosis correction methods often involve orthopedic procedures such as implant placement to stabilize movement and correct spinal deformity. The choice of surgical method is highly dependent on the location and nature of the fracture. Fractures with significant damage require a different approach compared to cases of minor injuries. Three dimensional finite element model of C1–L6 spine was used to simulate conditions with single cylindrical implant fixation under a vertical downward loading force 50 N and cylindrical screw types made of titanium alloy. The human spine, encompassing the cervical, thoracic, and lumbar regions, exhibits a complex biomechanical response when subjected to physiological loads. Displacement that occurs due to axial force can be the result of pedicle screw movement with vertebrae of the spine. Installation of 4 (four) rows of pedicle screws reduces the release of pedicle screws from the spine. The use of more fixation can reduce the stress distribution on the vertebrae of the spine.

Journal of Ocean Mechanical and Aerospace -science and engineering- (JOMAse)Vol. 69(1)
Andalas University (ID)
Universitas Andalas
Openalex Percentile: Top 93%
Medical Imaging and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Structural of Pedicle Screw on Biomechanical Characteristics of Spinal Scoliosis Correction Deformation — Meifal Rusli, Weriono Weriono, et al. · Journal of Ocean Mechanical and Aerospace -science and engineering- (JOMAse) (2025) | TGRS Research Map | TGRS