ON THE ISSUE OF STUDYING THE INFLUENCE OF STRUCTURAL FEATURES OF DOUBLE-GLAZED WINDOWS ON THE TOTAL HEAT LOSS OF BUILDINGS

Issues of the effective functioning of life support systems are always relevant and are reflected in the works of leading scientists. Consideration of the possibilities of reducing heat loss at all stages of transportation and operation is a promising direction in modern research. Heat supply refers to energy-intensive processes, heat losses in various areas are inevitable, so it is necessary to develop and improve measures that will minimize these losses and increase the efficiency of heat use. Calculations of heat losses are regulated by regulatory documents. Heat losses in buildings include losses through enclosing structures (walls) and losses through windows. Given that the area of window openings is significant, heat losses through windows are an important parameter that must be taken into account. Currently, it is possible to use various double-glazed windows that contribute to improving energy saving indicators. In addition to conventional single-chamber and double-chamber double-glazed windows, it is possible to use double-glazed windows filled with inert gas. The main advantage of single-chamber double-glazed windows is that they have a lighter construction, while filling with inert gas requires additional costs. The paper presents a comparative analysis of heat losses through window openings for four different designs. Heat losses through enclosing structures are considered. Data on losses resulting from infiltration are obtained. The total heat losses are shown. Analytical dependencies of heat losses on the outside air temperature are presented.

Authors

Institutions

Publication Details

Journal
Bulletin of Shakarim University Technical Sciences
Published
2025-03-29
DOI
https://doi.org/10.53360/2788-7995-2025-1(17)-41
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

ON THE ISSUE OF STUDYING THE INFLUENCE OF STRUCTURAL FEATURES OF DOUBLE-GLAZED WINDOWS ON THE TOTAL HEAT LOSS OF BUILDINGS

М. V. Yermolenko, О. А. Степанова, Valery V. Karpov, Zh. K. Akishov et al.
4 links
Bulletin of Shakarim University Technical Sciences
Building Energy and Comfort Optimization
article

ON THE ISSUE OF STUDYING THE INFLUENCE OF STRUCTURAL FEATURES OF DOUBLE-GLAZED WINDOWS ON THE TOTAL HEAT LOSS OF BUILDINGS

М. V. Yermolenko, О. А. Степанова, Valery V. Karpov, Zh. K. Akishov, A. D. Amandinova
article en

Abstract

Issues of the effective functioning of life support systems are always relevant and are reflected in the works of leading scientists. Consideration of the possibilities of reducing heat loss at all stages of transportation and operation is a promising direction in modern research. Heat supply refers to energy-intensive processes, heat losses in various areas are inevitable, so it is necessary to develop and improve measures that will minimize these losses and increase the efficiency of heat use. Calculations of heat losses are regulated by regulatory documents. Heat losses in buildings include losses through enclosing structures (walls) and losses through windows. Given that the area of window openings is significant, heat losses through windows are an important parameter that must be taken into account. Currently, it is possible to use various double-glazed windows that contribute to improving energy saving indicators. In addition to conventional single-chamber and double-chamber double-glazed windows, it is possible to use double-glazed windows filled with inert gas. The main advantage of single-chamber double-glazed windows is that they have a lighter construction, while filling with inert gas requires additional costs. The paper presents a comparative analysis of heat losses through window openings for four different designs. Heat losses through enclosing structures are considered. Data on losses resulting from infiltration are obtained. The total heat losses are shown. Analytical dependencies of heat losses on the outside air temperature are presented.

Bulletin of Shakarim University Technical Sciences(1(17))
Shakarim University (KZ)
Openalex Percentile: Top 93%
Building Energy and Comfort Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

ON THE ISSUE OF STUDYING THE INFLUENCE OF STRUCTURAL FEATURES OF DOUBLE-GLAZED WINDOWS ON THE TOTAL HEAT LOSS OF BUILDINGS — М. V. Yermolenko, О. А. Степанова, et al. · Bulletin of Shakarim University Technical Sciences (2025) | TGRS Research Map | TGRS