Uncertainty Propagation From Projections to Region Counts in Tomographic Imaging: Application to Radiopharmaceutical Dosimetry

Radiopharmaceutical therapies (RPTs) pre- sent a major opportunity to improve cancer therapy. Although many current RPTs use the same injected activity for all patients, there is interest in using absorbed dose measurements to enable personalized prescriptions. However, image-based absorbed dose calculations incur uncertainties from calibration factors, partial volume effects and segmentation methods. While previously published dose estimation protocols incorporate these uncertainties, they do not account for uncertainty that originates from Poisson noise in the projection data that gets propagated through reconstruction algorithms. This effect should be accounted for to adequately estimate the total uncertainty in absorbed dose estimates. This paper proposes a computationally practical algorithm that propagates uncertainty from projection data through clinical reconstruction algorithms to obtain uncertainties on the total activity within volumes of interest (VOIs). The algorithm is first validated on ${}^{{177}}$ Lu and ${}^{{225}}$ Ac phantom data by comparing estimated uncertainties from individual SPECT acquisitions to empirical estimates obtained from multiple acquisitions. It is then applied to (i) Monte Carlo and (ii) multi-time point ${}^{{177}}$ Lu-DOTATATE and ${}^{{225}}$ Ac-PSMA-617 patient data for time integrated activity (TIA) uncertainty estimation. The outcomes of this work are two-fold: (i) the proposed uncertainty estimation algorithm is validated, and (ii) the propagation of VOI uncertainties to TIA uncertainty is validated with Monte Carlo data and applied to patient data. The proposed algorithm is made publicly available in the open-source image reconstruction library PyTomography and in the SPECT reconstruction extension of 3D Slicer.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Medical Imaging
Published
2025-04-14
DOI
https://doi.org/10.1109/tmi.2025.3560330
Citations
1
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
1.36

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Uncertainty Propagation From Projections to Region Counts in Tomographic Imaging: Application to Radiopharmaceutical Dosimetry

Pedro L. Esquinas, Lucas Polson, Arman Rahmim, Sara Kurkowska et al.
1 citations
IEEE Transactions on Medical Imaging
Medical Imaging Techniques and Applications
1.36
article

Uncertainty Propagation From Projections to Region Counts in Tomographic Imaging: Application to Radiopharmaceutical Dosimetry

Pedro L. Esquinas, Lucas Polson, Arman Rahmim, Sara Kurkowska, François Bénard, Peyman Sheikhzadeh, Carlos Uribe, Mehrshad Abbasi, Changqiao Li
article en
1 citations

Abstract

Radiopharmaceutical therapies (RPTs) pre- sent a major opportunity to improve cancer therapy. Although many current RPTs use the same injected activity for all patients, there is interest in using absorbed dose measurements to enable personalized prescriptions. However, image-based absorbed dose calculations incur uncertainties from calibration factors, partial volume effects and segmentation methods. While previously published dose estimation protocols incorporate these uncertainties, they do not account for uncertainty that originates from Poisson noise in the projection data that gets propagated through reconstruction algorithms. This effect should be accounted for to adequately estimate the total uncertainty in absorbed dose estimates. This paper proposes a computationally practical algorithm that propagates uncertainty from projection data through clinical reconstruction algorithms to obtain uncertainties on the total activity within volumes of interest (VOIs). The algorithm is first validated on ${}^{{177}}$ Lu and ${}^{{225}}$ Ac phantom data by comparing estimated uncertainties from individual SPECT acquisitions to empirical estimates obtained from multiple acquisitions. It is then applied to (i) Monte Carlo and (ii) multi-time point ${}^{{177}}$ Lu-DOTATATE and ${}^{{225}}$ Ac-PSMA-617 patient data for time integrated activity (TIA) uncertainty estimation. The outcomes of this work are two-fold: (i) the proposed uncertainty estimation algorithm is validated, and (ii) the propagation of VOI uncertainties to TIA uncertainty is validated with Monte Carlo data and applied to patient data. The proposed algorithm is made publicly available in the open-source image reconstruction library PyTomography and in the SPECT reconstruction extension of 3D Slicer.

IEEE Transactions on Medical ImagingVol. 44(8)
University of British Columbia (CA), University of Tehran (IR)
Canadian Network for Research and Innovation in Machining Technology, Natural Sciences and Engineering Research Council of Canada
Zero hunger
Openalex Percentile: Top 21%
Medical Imaging Techniques and Applications
1.36
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.