Fast Acquisition of Sensor Array Geometry of Whole-Head Magnetoencephalograph Systems Using a Neural Network

Acquiring position, orientation, and sensitivity of magnetometers in a helmet-shaped sensor array is crucial for accurate current source reconstruction in magnetoencephalography. To determine these parameters for each magnetometer, we utilize a spherical calibration coil array. In our previous study, the position and orientation of each magnetometer were determined as the solution of an inverse problem through a numerical search that minimized the difference between the theoretical magnetic field signals from each coil and the measured signals detected by the magnetometer. In this study, we applied a deep neural network to estimate the position and orientation of each magnetometer in the helmet-shaped sensor array without solving inverse problem. A total of 223 million pairs of a given magnetometer's five parameters (x, y, z, θ, and ϕ) and the corresponding theoretical magnetic field signals from the coils were used to train the neural network. The training process required approximately 53 hours using a commercially available GPU-equipped computer. The trained neural network was then applied to acquire the sensor geometry from magnetic field data obtained during the conventional calibration procedure for a 160-channel whole-head magnetoencephalograph system using a spherical calibration coil array. The position and orientation of each magnetometer estimated by this method deviated by an average of 0.65 mm and 0.51 degree, respectively, from those obtained via the conventional inverse problem approach. The acquisition of the geometry for all 160 magnetometers required less than 8 ms. With such high-speed acquisition, this approach opens possibilities for future applications in acquiring positional information of wearable sensor arrays whose structures change in real-time.

Authors

Institutions

Publication Details

Journal
IEEE Magnetics Letters
Published
2025-01-01
DOI
https://doi.org/10.1109/lmag.2025.3560886
Citations
2
Primary Topic
Neural Networks and Applications
Type
article
Field-Weighted Citation Impact
4.96
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fast Acquisition of Sensor Array Geometry of Whole-Head Magnetoencephalograph Systems Using a Neural Network

Gen Uehara, Yoshiaki Adachi, Daisuke Oyama
2 citations
IEEE Magnetics Letters
Neural Networks and Applications
4.96
article

Fast Acquisition of Sensor Array Geometry of Whole-Head Magnetoencephalograph Systems Using a Neural Network

Gen Uehara, Yoshiaki Adachi, Daisuke Oyama
article en
2 citations

Abstract

Acquiring position, orientation, and sensitivity of magnetometers in a helmet-shaped sensor array is crucial for accurate current source reconstruction in magnetoencephalography. To determine these parameters for each magnetometer, we utilize a spherical calibration coil array. In our previous study, the position and orientation of each magnetometer were determined as the solution of an inverse problem through a numerical search that minimized the difference between the theoretical magnetic field signals from each coil and the measured signals detected by the magnetometer. In this study, we applied a deep neural network to estimate the position and orientation of each magnetometer in the helmet-shaped sensor array without solving inverse problem. A total of 223 million pairs of a given magnetometer's five parameters (x, y, z, θ, and ϕ) and the corresponding theoretical magnetic field signals from the coils were used to train the neural network. The training process required approximately 53 hours using a commercially available GPU-equipped computer. The trained neural network was then applied to acquire the sensor geometry from magnetic field data obtained during the conventional calibration procedure for a 160-channel whole-head magnetoencephalograph system using a spherical calibration coil array. The position and orientation of each magnetometer estimated by this method deviated by an average of 0.65 mm and 0.51 degree, respectively, from those obtained via the conventional inverse problem approach. The acquisition of the geometry for all 160 magnetometers required less than 8 ms. With such high-speed acquisition, this approach opens possibilities for future applications in acquiring positional information of wearable sensor arrays whose structures change in real-time.

IEEE Magnetics LettersVol. 16
Kanazawa Institute of Technology (JP)
Affordable and clean energy
Openalex Percentile: Top 6%
Neural Networks and Applications
4.96
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.