Design and Validation of Substrate Integrated Waveguide-Based Blood Glucose Measurement Sensor

The increasing global prevalence of diabetes necessitates the development of accurate, reliable, and miniaturised glucose sensing technologies. Microwave-based sensors offer a promising alternative to conventional electrochemical methods due to their less invasive nature and real-time monitoring capabilities. However, previous microwave glucose sensors have often lacked comprehensive validation, limiting their practical usability. Many existing studies rely on simplified simulations without detailed parametric studies or fail to establish a strong correlation between theoretical models and experimental results, resulting in discrepancies in sensor performance. This study introduces a Cross-Slot Substrate Integrated Waveguide (CSSIW) sensor that overcomes these limitations by implementing a rigorous multi-level validation approach, including analytical modeling, full-wave electromagnetic simulations, and experimental verification. The sensor’s X-slot structure enhances electric field concentration, significantly improving sensitivity while maintaining a compact form factor (13×9 mm). Through eigenmode analysis and parametric studies, the sensor’s resonant frequency shift is optimised to detect glucose concentration variations with high precision. Experimental validation using glucose solutions at physiological concentrations (20–200 mg/dL) demonstrates a sensitivity of 0.563 MHz/(mg/dL), closely aligning with simulated results (0.415 MHz/(mg/dL)), confirming its accuracy and robustness. Compared to previous works, this study addresses prior shortcomings by providing a detailed investigation of field interactions, quality factor evaluation, and environmental dependencies, ensuring a comprehensive understanding of the CSSIW sensor’s performance. The findings confirm that the proposed sensor achieves low insertion loss (1.13 dB), strong impedance matching (-18.7 dB return loss), and full physiological range coverage, making it a promising candidate for next-generation glucose monitoring solutions.

Authors

Institutions

Publication Details

Journal
IEEE Sensors Journal
Published
2025-04-14
DOI
https://doi.org/10.1109/jsen.2025.3558584
Citations
6
Primary Topic
Spectroscopy Techniques in Biomedical and Chemical Research
Type
article
Field-Weighted Citation Impact
9.80
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and Validation of Substrate Integrated Waveguide-Based Blood Glucose Measurement Sensor

Balázs Benyó, Ameer B. Alsultani, J. Geoffrey Chase
6 citations
IEEE Sensors Journal
Spectroscopy Techniques in Biomedical and Chemical Research
9.80
article

Design and Validation of Substrate Integrated Waveguide-Based Blood Glucose Measurement Sensor

Balázs Benyó, Ameer B. Alsultani, J. Geoffrey Chase
article en
6 citations

Abstract

The increasing global prevalence of diabetes necessitates the development of accurate, reliable, and miniaturised glucose sensing technologies. Microwave-based sensors offer a promising alternative to conventional electrochemical methods due to their less invasive nature and real-time monitoring capabilities. However, previous microwave glucose sensors have often lacked comprehensive validation, limiting their practical usability. Many existing studies rely on simplified simulations without detailed parametric studies or fail to establish a strong correlation between theoretical models and experimental results, resulting in discrepancies in sensor performance. This study introduces a Cross-Slot Substrate Integrated Waveguide (CSSIW) sensor that overcomes these limitations by implementing a rigorous multi-level validation approach, including analytical modeling, full-wave electromagnetic simulations, and experimental verification. The sensor’s X-slot structure enhances electric field concentration, significantly improving sensitivity while maintaining a compact form factor (13×9 mm). Through eigenmode analysis and parametric studies, the sensor’s resonant frequency shift is optimised to detect glucose concentration variations with high precision. Experimental validation using glucose solutions at physiological concentrations (20–200 mg/dL) demonstrates a sensitivity of 0.563 MHz/(mg/dL), closely aligning with simulated results (0.415 MHz/(mg/dL)), confirming its accuracy and robustness. Compared to previous works, this study addresses prior shortcomings by providing a detailed investigation of field interactions, quality factor evaluation, and environmental dependencies, ensuring a comprehensive understanding of the CSSIW sensor’s performance. The findings confirm that the proposed sensor achieves low insertion loss (1.13 dB), strong impedance matching (-18.7 dB return loss), and full physiological range coverage, making it a promising candidate for next-generation glucose monitoring solutions.

IEEE Sensors JournalVol. 25(11)
University of Canterbury (NZ), Budapest University of Technology and Economics (HU)
Openalex Percentile: Top 2%
Spectroscopy Techniques in Biomedical and Chemical Research
9.80
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.