Internal Energy Balancing Control of a Modular Multilevel Converter as Part of a Hybrid Transformer

Hybrid transformers (HTs) can provide voltage and current compensation in the utility grid. HTs include a line-frequency transformer and a converter rated for partial transformer power. This paper focuses on the internal energy balancing process of a modular multilevel converter (MMC) as part of an HT. The output voltages of the MMC have equal frequency and equal phase angles, but different amplitudes in this application. In this paper it is shown that these two features result in steady-state control errors and variable control loop gains when a conventional MMC internal energy balancing method is applied. In this article, a customized control scheme for the MMC is developed that solves these problems. The theoretical analysis is validated through tests on a scaled-down prototype.

Authors

Institutions

Publication Details

Journal
IEEE Open Journal of Power Electronics
Published
2025-01-01
DOI
https://doi.org/10.1109/ojpel.2025.3560808
Primary Topic
Electric Power Systems and Control
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Internal Energy Balancing Control of a Modular Multilevel Converter as Part of a Hybrid Transformer

Maurice Roes, Henk Huisman, C. G. E. Wijnands, Rui Wang
IEEE Open Journal of Power Electronics
Electric Power Systems and Control
article

Internal Energy Balancing Control of a Modular Multilevel Converter as Part of a Hybrid Transformer

Maurice Roes, Henk Huisman, C. G. E. Wijnands, Rui Wang
article en

Abstract

Hybrid transformers (HTs) can provide voltage and current compensation in the utility grid. HTs include a line-frequency transformer and a converter rated for partial transformer power. This paper focuses on the internal energy balancing process of a modular multilevel converter (MMC) as part of an HT. The output voltages of the MMC have equal frequency and equal phase angles, but different amplitudes in this application. In this paper it is shown that these two features result in steady-state control errors and variable control loop gains when a conventional MMC internal energy balancing method is applied. In this article, a customized control scheme for the MMC is developed that solves these problems. The theoretical analysis is validated through tests on a scaled-down prototype.

IEEE Open Journal of Power ElectronicsVol. 6
Eindhoven University of Technology (NL)
Nederlandse Organisatie voor Wetenschappelijk Onderzoek
Affordable and clean energy
Openalex Percentile: Top 94%
Electric Power Systems and Control
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.