A full-scale evaluation of the effects of different disinfection methods on the removal of contaminants of emerging concern

Most of the past studies have focused on the effects of secondary treatment processes of Wastewater Treatment Plants (WWTPs) in the removal of Contaminants of Emerging Concern (CECs). Limited data are indeed available in the scientific literature on the capability of disinfection in the reduction of CECs. The present study, conducted in collaboration with one of the largest Italian utilities, aimed at completing the knowledge about the effects on CECs due to the most common disinfection methods: peracetic acid, sand filtration followed by UV radiation and sodium hypochlorite. The study was conducted in three full-scale WWTPs, each one equipped with one of these methods. The results demonstrated a very low reduction rate in all cases. The peracetic acid disinfection showed a better removal of methamphetamine and sulfamethoxazole; when its dosage was increased in laboratory tests, an improvement was observed for lincomycin (up to 61 %) only. The chlorination provided the lowest removal efficiency. The combination of sand filtration and UV radiation exhibited a better degradation for benzoylecgonine, sulfamethoxazole, ketoprofen and trimethoprim. The environmental risk of the disinfected effluent ranged from low to medium, depending on whether it is discharged into a river or applied to soil; the agricultural reuse showed a low sanitary risk. • Chlorine, peracetic acid and ultraviolet radiation disinfection could not extensively remove Contaminants of Emerging Concern • Higher dosage of peracetic acid increased lincomycin removal • Filtration with ultraviolet disinfection better removed some pharmaceuticals • Environmental and sanitary risks due to the disinfected effluent were found in the low-medium range

Authors

Institutions

Publication Details

Journal
Journal of Water Process Engineering
Published
2025-04-14
DOI
https://doi.org/10.1016/j.jwpe.2025.107686
Primary Topic
Pharmaceutical and Antibiotic Environmental Impacts
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A full-scale evaluation of the effects of different disinfection methods on the removal of contaminants of emerging concern

Camilla Di Marcantonio, Agostina Chiavola, Valentina Gioia, Alessandro Frugis et al.
Journal of Water Process Engineering
Pharmaceutical and Antibiotic Environmental Impacts
article

A full-scale evaluation of the effects of different disinfection methods on the removal of contaminants of emerging concern

Camilla Di Marcantonio, Agostina Chiavola, Valentina Gioia, Alessandro Frugis, Simone Leoni, Massimo Spizzirri, Serena Lamberti
article en

Abstract

Most of the past studies have focused on the effects of secondary treatment processes of Wastewater Treatment Plants (WWTPs) in the removal of Contaminants of Emerging Concern (CECs). Limited data are indeed available in the scientific literature on the capability of disinfection in the reduction of CECs. The present study, conducted in collaboration with one of the largest Italian utilities, aimed at completing the knowledge about the effects on CECs due to the most common disinfection methods: peracetic acid, sand filtration followed by UV radiation and sodium hypochlorite. The study was conducted in three full-scale WWTPs, each one equipped with one of these methods. The results demonstrated a very low reduction rate in all cases. The peracetic acid disinfection showed a better removal of methamphetamine and sulfamethoxazole; when its dosage was increased in laboratory tests, an improvement was observed for lincomycin (up to 61 %) only. The chlorination provided the lowest removal efficiency. The combination of sand filtration and UV radiation exhibited a better degradation for benzoylecgonine, sulfamethoxazole, ketoprofen and trimethoprim. The environmental risk of the disinfected effluent ranged from low to medium, depending on whether it is discharged into a river or applied to soil; the agricultural reuse showed a low sanitary risk. • Chlorine, peracetic acid and ultraviolet radiation disinfection could not extensively remove Contaminants of Emerging Concern • Higher dosage of peracetic acid increased lincomycin removal • Filtration with ultraviolet disinfection better removed some pharmaceuticals • Environmental and sanitary risks due to the disinfected effluent were found in the low-medium range

Journal of Water Process EngineeringVol. 73
Sapienza University of Rome (IT), European Automobile Manufacturers Association (BE)
Zero hunger
Openalex Percentile: Top 95%
Pharmaceutical and Antibiotic Environmental Impacts
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.