Investigating proton exchange membrane electrolyzer performance under variable renewable power: Insights into voltage and stack efficiency

This study investigates the short-term performance and efficiency of a benchtop proton exchange membrane (PEM) electrolyzer for hydrogen production under dynamic power input conditions representative of renewable energy sources . Experiments were conducted to evaluate the effects of current fluctuation characteristics—specifically frequency and standard deviation—on electrolyzer behavior. Results demonstrate that rapid and high-amplitude current fluctuations lead to increased power consumption , voltage instability, and reductions in both stack and voltage efficiency when compared to steady-state operation. Smoother current profiles, characterized by lower standard deviations and lower frequencies, improved system stability , efficiency, and hydrogen production rates. Additionally, fully transient tests using real wind power profiles revealed the highest power consumption and operational variability, underscoring the challenges posed by fluctuating renewable inputs. While the findings provide valuable insights into the immediate response of PEM electrolyzers under dynamic conditions, they are limited to short-term observations. Further long-duration studies are necessary to evaluate long-term stability and degradation effects. Overall, this research contributes to the understanding of PEM electrolyzer integration with intermittent renewable energy sources and highlights the importance of power regulation strategies for improving efficiency and operational stability in hydrogen production systems. • Investigated short-term dynamic performance of a benchtop PEM electrolyzer under fluctuating power inputs. • Power fluctuation amplitude reduces electrolyzer efficiency and stability significantly. • Power fluctuation frequency minimally impacts electrolyzer efficiency and stability. • Fully transient tests using real wind data showed highest power variability and efficiency losses.

Authors

Institutions

Publication Details

Journal
Journal of Electroanalytical Chemistry
Published
2025-04-14
DOI
https://doi.org/10.1016/j.jelechem.2025.119130
Citations
4
Primary Topic
Hybrid Renewable Energy Systems
Type
article
Field-Weighted Citation Impact
2.13
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Investigating proton exchange membrane electrolyzer performance under variable renewable power: Insights into voltage and stack efficiency

Hsi‐Wu Wong, Ertan Ağar, Majid Ali, Xinfang Jin et al.
4 citations
Journal of Electroanalytical Chemistry
Hybrid Renewable Energy Systems
2.13
article

Investigating proton exchange membrane electrolyzer performance under variable renewable power: Insights into voltage and stack efficiency

Hsi‐Wu Wong, Ertan Ağar, Majid Ali, Xinfang Jin, Fuqiang Liu, Snigdha Rashinkar, Mihriye Doga Tekbas
article en
4 citations

Abstract

This study investigates the short-term performance and efficiency of a benchtop proton exchange membrane (PEM) electrolyzer for hydrogen production under dynamic power input conditions representative of renewable energy sources . Experiments were conducted to evaluate the effects of current fluctuation characteristics—specifically frequency and standard deviation—on electrolyzer behavior. Results demonstrate that rapid and high-amplitude current fluctuations lead to increased power consumption , voltage instability, and reductions in both stack and voltage efficiency when compared to steady-state operation. Smoother current profiles, characterized by lower standard deviations and lower frequencies, improved system stability , efficiency, and hydrogen production rates. Additionally, fully transient tests using real wind power profiles revealed the highest power consumption and operational variability, underscoring the challenges posed by fluctuating renewable inputs. While the findings provide valuable insights into the immediate response of PEM electrolyzers under dynamic conditions, they are limited to short-term observations. Further long-duration studies are necessary to evaluate long-term stability and degradation effects. Overall, this research contributes to the understanding of PEM electrolyzer integration with intermittent renewable energy sources and highlights the importance of power regulation strategies for improving efficiency and operational stability in hydrogen production systems. • Investigated short-term dynamic performance of a benchtop PEM electrolyzer under fluctuating power inputs. • Power fluctuation amplitude reduces electrolyzer efficiency and stability significantly. • Power fluctuation frequency minimally impacts electrolyzer efficiency and stability. • Fully transient tests using real wind data showed highest power variability and efficiency losses.

Journal of Electroanalytical ChemistryVol. 988
University of Massachusetts Lowell (US), The University of Texas at Dallas (US)
Affordable and clean energy
Openalex Percentile: Top 13%
Hybrid Renewable Energy Systems
2.13
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.