Carbon Paste Electrode-Modified Imprinted Zeolite X and Its Performance as a Potentiometric and Voltammetric Sensor for Cholesterol Analysis

Carbon paste electrode-modified imprinted zeolite X has been developed as a potentiometry and voltammetry sensor to monitor cholesterol levels in the body. This is crucial to detect early health risks caused by high cholesterol levels. The modified electrode was fabricated with a mass ratio of activated carbon, paraffin, and imprinted zeolite X of 12:7:1. Potentiometric measurement produced a linear dynamic range of 10−6–10−3 M, Nernst factor of 27.12 mV/decade, a detection limit of 1.12 × 10−6 M, precision of 99.7% (n = 3), and accuracy of 99.8% (n = 5). Using the electrode for up to 56 measurements over 6 weeks did not significantly decrease its performance. The presence of glucose did not interfere with cholesterol analysis by potentiometry. The modified electrode was applied to analyze cholesterol voltammetrically at the optimum deposition potential of 0.4 V, deposition time of 60 s, and a scan rate of 100 mV/s. Voltammetric analysis of cholesterol resulted in a detection limit of 7.2 mg/L (1.86 µM), precision of 96–99%, accuracy of 74–114%, sensitivity of 7.1 nA.L/mg/cm2, and recovery of 87.2% (n = 3). The glucose and urea in various concentrations cause less than 5% current deviations.

Authors

Publication Details

Journal
Indonesian Journal of Chemistry
Published
2025-03-25
DOI
https://doi.org/10.22146/ijc.99700
Citations
3
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
2.19
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Carbon Paste Electrode-Modified Imprinted Zeolite X and Its Performance as a Potentiometric and Voltammetric Sensor for Cholesterol Analysis

Alfa Akustia Widati, Miratul Khasanah, Nadya Maya Severia, Citra Marantika Nur Oktaviana et al.
3 citations
Indonesian Journal of Chemistry
Electrochemical sensors and biosensors
2.19
article

Carbon Paste Electrode-Modified Imprinted Zeolite X and Its Performance as a Potentiometric and Voltammetric Sensor for Cholesterol Analysis

Alfa Akustia Widati, Miratul Khasanah, Nadya Maya Severia, Citra Marantika Nur Oktaviana, Evrillia Puspitasari, Naftalia Wirdatul Ummah, Ziana Alviani
article en
3 citations

Abstract

Carbon paste electrode-modified imprinted zeolite X has been developed as a potentiometry and voltammetry sensor to monitor cholesterol levels in the body. This is crucial to detect early health risks caused by high cholesterol levels. The modified electrode was fabricated with a mass ratio of activated carbon, paraffin, and imprinted zeolite X of 12:7:1. Potentiometric measurement produced a linear dynamic range of 10−6–10−3 M, Nernst factor of 27.12 mV/decade, a detection limit of 1.12 × 10−6 M, precision of 99.7% (n = 3), and accuracy of 99.8% (n = 5). Using the electrode for up to 56 measurements over 6 weeks did not significantly decrease its performance. The presence of glucose did not interfere with cholesterol analysis by potentiometry. The modified electrode was applied to analyze cholesterol voltammetrically at the optimum deposition potential of 0.4 V, deposition time of 60 s, and a scan rate of 100 mV/s. Voltammetric analysis of cholesterol resulted in a detection limit of 7.2 mg/L (1.86 µM), precision of 96–99%, accuracy of 74–114%, sensitivity of 7.1 nA.L/mg/cm2, and recovery of 87.2% (n = 3). The glucose and urea in various concentrations cause less than 5% current deviations.

Indonesian Journal of ChemistryVol. 25(2)
Openalex Percentile: Top 13%
Electrochemical sensors and biosensors
2.19
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.