The reproducibility of [68Ga]Ga-FAPI-04 PET uptake parameters at 15 min and 60 min post-injection
Gallium-68 labeled fibroblast activation protein inhibitor ([68Ga]Ga-FAPI-04) can be visualized just 15 min post-injection. However, the appearance of imaging at 15 and 60 min remains unclear. This study aimed to explore the relationship between quantitative values in [68Ga]Ga-FAPI-04 PET, specifically at 15 and 60 minutes post-injection, in patients with various tumor. We enrolled 30 patients with cancer who underwent [68Ga]Ga-FAPI-04 PET/CT scan between January 2021 and February 2025 at our institute. Image acquisition was performed using a PET/CT scanner at 15 min and 60 min after [68Ga]Ga-FAPI-04 injection. The maximum, mean and peak standardized uptake value (SUV<sub>max</sub>, SUV<sub>mean</sub> and SUV<sub>peak</sub>), tumor-to-liver ratio (TLR), and uptake tumor volume (UTV) were measured in the region of interest of the target lesion, liver SUV<sub>mean</sub> (SUV<sub>liver</sub>) was also measured. Correlation coefficients of the between-image variables were evaluated by Spearman's rank correlation test. Agreement between the variables was evaluated by Bland-Altman plots with 95% limits of agreement. The SUV<sub>max</sub>, SUV<sub>mean</sub>, SUV<sub>peak</sub> and UTV in tumors of all examinations were decreased from 15 min to 60 min. The SUV<sub>max</sub>, SUV<sub>mean</sub>, SUV<sub>peak</sub>, TLR, and UTV at 15 min and 60 min were highly correlated (<i>r<sub>s</sub></i> = 0.945, 0.949, 0.959, 0.943, and 0.958; <i>P</i> < 0.001). The 95% limits of agreement ranged from -27.8 to 29.1 with a mean of 0.7 and -24.1 to 29.5 with a mean of 2.7 for SUV<sub>max</sub> and SUV<sub>mean</sub>, respectively. Other PET metrics demonstrated that all limits are above ± 30% between 15 min and 60 min. We observed a high correlation between the quantitative values at 15 min and 60 min. Meanwhile, 15 min and 60 min [68Ga]Ga-FAPI-04 PET SUV<sub>max</sub> and SUV<sub>mean</sub> have clinically acceptable reproducibility, and 15 min scan is feasible for all patients, but SUV<sub>peak</sub>, TLR and UTV should not be used interchangeably.
Authors
- Hongyu Meng (ORCID: https://orcid.org/0000-0002-3495-7850)
Institutions
- Tongji University (CN)
- Shanghai Tenth People's Hospital (CN)
Publication Details
- Journal
- American Journal of Nuclear Medicine and Molecular Imaging
- Published
- 2025-01-01
- DOI
- https://doi.org/10.62347/dcgc3250
- Citations
- 1
- Primary Topic
- Peptidase Inhibition and Analysis
- Type
- article
- Field-Weighted Citation Impact
- 1.05