Performance analysis on the feasibility and accuracy of triple-wavelength integrated path absorption lidar for atmospheric CO<sub>2</sub> measurement

This study focuses on exploring the feasibility and accuracy of triple-wavelength integrated path differential absorption (IPDA) lidar to measure the atmospheric <i>C</i><i>O</i><sub>2</sub> column concentration. Traditional IPDA lidar-based two wavelengths for measuring <i>C</i><i>O</i><sub>2</sub> are highly dependent on meteorological parameters such as temperature, pressure, and humidity. Multi-wavelength IPDA lidar has shown potential for overcoming these challenges. By introducing a third wavelength into the IPDA lidar, we could further reduce interference from water vapor and decrease the sensitivity to atmospheric parameters, such as temperature and pressure. Simulation results indicate that the triple-wavelength IPDA lidar can significantly reduce system errors compared to the dual-wavelength lidar. The global system error is reduced by an average error of 0.156 ppm, with a mean total error of 0.517 ppm for the triple-wavelength IPDA lidar. This study provides theoretical support for the optimization and application of future lidar systems in atmospheric <i>C</i><i>O</i><sub>2</sub> monitoring.

Authors

Publication Details

Journal
Applied Optics
Published
2025-04-14
DOI
https://doi.org/10.1364/ao.560607
Primary Topic
Spectroscopy and Laser Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance analysis on the feasibility and accuracy of triple-wavelength integrated path absorption lidar for atmospheric CO2 measurement

Xiaopeng Zhu, Jiqiao Liu, Chuncan Fan, Weibiao Chen et al.
Applied Optics
Spectroscopy and Laser Applications
article

Performance analysis on the feasibility and accuracy of triple-wavelength integrated path absorption lidar for atmospheric CO2 measurement

Xiaopeng Zhu, Jiqiao Liu, Chuncan Fan, Weibiao Chen, Jing Yang, Chen Cheng, Yuan Xie, Wu Zitong
article en

Abstract

This study focuses on exploring the feasibility and accuracy of triple-wavelength integrated path differential absorption (IPDA) lidar to measure the atmospheric <i>C</i><i>O</i><sub>2</sub> column concentration. Traditional IPDA lidar-based two wavelengths for measuring <i>C</i><i>O</i><sub>2</sub> are highly dependent on meteorological parameters such as temperature, pressure, and humidity. Multi-wavelength IPDA lidar has shown potential for overcoming these challenges. By introducing a third wavelength into the IPDA lidar, we could further reduce interference from water vapor and decrease the sensitivity to atmospheric parameters, such as temperature and pressure. Simulation results indicate that the triple-wavelength IPDA lidar can significantly reduce system errors compared to the dual-wavelength lidar. The global system error is reduced by an average error of 0.156 ppm, with a mean total error of 0.517 ppm for the triple-wavelength IPDA lidar. This study provides theoretical support for the optimization and application of future lidar systems in atmospheric <i>C</i><i>O</i><sub>2</sub> monitoring.

Applied OpticsVol. 64(14)
Openalex Percentile: Top 93%
Spectroscopy and Laser Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.