On-site salt iodine detector (OSID) kit: An alternative tool for salt iodization monitoring

Iodine fortification of cooking salt prevents iodine deficiency, but current monitoring methods are labor-intensive. Here, we validated the On-Site Salt Iodine Detector (OSID) kit as a reliable tool for salt iodine analysis. The OSID kit was optimized for a salt weight (346.1 ± 4.9 mg) and volume of solution D (39.1 ± 1.2 µL), enabling 100 sample analyses. The validation was by its linearity (10.0-50.0 mg/Kg, R<sup>2</sup> = 0.9956) with limit of detection (LOD, 3.6 mg/Kg), method recovery (89.5 %-99.4 %), intra-assay imprecision (coefficient of variation, CV 5.7 %), inter-assay imprecision (CV 7.0 %) and inter-operator imprecision (CV 6.1 %). A 30.0 mg/Kg iodate and sample S4 used as quality control (QC) for ten days monitoring which resulted within the range of mean±2×standard deviation (SD) (27.2 ± 2.4 mg/Kg and 21.6 ± 5.3 mg/Kg, respectively). The OSID kit showed strong agreement in a Blant-Altman plot when compared with UHPLC (60 salt samples) indicating a reliable and cost-effective alternative for salt iodine monitoring.•The optimization of salt weight and volume of solution D allows 100 analyses per kit.•The OSID kit imprecision validation of <10 % demonstrate excellent precision and reliability of the method.•The result comparison between the OSID kit and the UHPLC reference method suggest a strong agreement in a Blant-Altman plot.

Authors

Institutions

Publication Details

Journal
MethodsX
Published
2025-04-14
DOI
https://doi.org/10.1016/j.mex.2025.103314
Citations
1
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.74

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

On-site salt iodine detector (OSID) kit: An alternative tool for salt iodization monitoring

Aswir Abd Rashed, Mohd Azerulazree Jamilan, Ahmad Ali Zainuddin, Nurul Aznyda Norizan et al.
1 citations
MethodsX
Analytical Chemistry and Sensors
0.74
article

On-site salt iodine detector (OSID) kit: An alternative tool for salt iodization monitoring

Aswir Abd Rashed, Mohd Azerulazree Jamilan, Ahmad Ali Zainuddin, Nurul Aznyda Norizan, Mohd Fairulnizal Md Noh, Filza Noor Asari, Noor Muhammad
article en
1 citations

Abstract

Iodine fortification of cooking salt prevents iodine deficiency, but current monitoring methods are labor-intensive. Here, we validated the On-Site Salt Iodine Detector (OSID) kit as a reliable tool for salt iodine analysis. The OSID kit was optimized for a salt weight (346.1 ± 4.9 mg) and volume of solution D (39.1 ± 1.2 µL), enabling 100 sample analyses. The validation was by its linearity (10.0-50.0 mg/Kg, R<sup>2</sup> = 0.9956) with limit of detection (LOD, 3.6 mg/Kg), method recovery (89.5 %-99.4 %), intra-assay imprecision (coefficient of variation, CV 5.7 %), inter-assay imprecision (CV 7.0 %) and inter-operator imprecision (CV 6.1 %). A 30.0 mg/Kg iodate and sample S4 used as quality control (QC) for ten days monitoring which resulted within the range of mean±2×standard deviation (SD) (27.2 ± 2.4 mg/Kg and 21.6 ± 5.3 mg/Kg, respectively). The OSID kit showed strong agreement in a Blant-Altman plot when compared with UHPLC (60 salt samples) indicating a reliable and cost-effective alternative for salt iodine monitoring.•The optimization of salt weight and volume of solution D allows 100 analyses per kit.•The OSID kit imprecision validation of <10 % demonstrate excellent precision and reliability of the method.•The result comparison between the OSID kit and the UHPLC reference method suggest a strong agreement in a Blant-Altman plot.

MethodsXVol. 14
Ministry of Health (MY)
Kementerian Kesihatan Malaysia
Openalex Percentile: Top 35%
Analytical Chemistry and Sensors
0.74
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

On-site salt iodine detector (OSID) kit: An alternative tool for salt iodization monitoring — Aswir Abd Rashed, Mohd Azerulazree Jamilan, et al. · MethodsX (2025) | TGRS Research Map | TGRS