Comparison of flow cytometry and heterotrophic plate count methods for dialysis water microbial monitoring

Water is an essential component of renal replacement therapy by dialysis. Haemodialysis patients undergoing 4-hour dialysis sessions, thrice weekly, may be exposed to more than 360 L of dialysis fluid per week. Dialysis water and ultrapure dialysis fluids have been established as a prerequisite for online convective therapies (namely haemodiafiltration), to improve biocompatibility of the dialysis system and to reduce inflammation profile of the dialysis patients. The microbial quality of dialysis water should be monitored regularly to demonstrate the effectiveness of the disinfection protocol. Current water and dialysis fluids microbial quality assessment is typically done via heterotrophic plate counts (HPC) and endotoxins analysis. Plate counts methodology provides information on the microbial content of the water only after a considerable incubation time (typically 7 days). Flow cytometry (FCM), as a rapid alternative method, provides the possibility of real-time corrective actions and greater patient safety. In this study, we compared the outcomes of dialysis water microbial quality in an existing dialysis clinic, using two different measurement methods, HPC and FCM, to test the possible benefits of applying FCM as a valid alternative method for dialysis water microbial monitoring. We conclude that FCM offers higher sensitivity than HPC for microbial monitoring of dialysis water, potentially enabling earlier corrective actions. More extensive and larger studies are needed, namely, to evaluate the possible added value of FCM method in dialysis fluids monitoring. If the FCM method is confirmed, it will be necessary to establish maximum allowable levels and typical action levels for dialysis water and dialysis fluids quality when using FCM.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-04-14
DOI
https://doi.org/10.1038/s41598-025-96597-0
Citations
2
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
1.35
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of flow cytometry and heterotrophic plate count methods for dialysis water microbial monitoring

Juliane Feurle, Aníbal Ferreira, Bernard Canaud, Célia Gil et al.
2 citations
Scientific Reports
Biosensors and Analytical Detection
1.35
article

Comparison of flow cytometry and heterotrophic plate count methods for dialysis water microbial monitoring

Juliane Feurle, Aníbal Ferreira, Bernard Canaud, Célia Gil, Rui Lucena, Pedro Ponce
article en
2 citations

Abstract

Water is an essential component of renal replacement therapy by dialysis. Haemodialysis patients undergoing 4-hour dialysis sessions, thrice weekly, may be exposed to more than 360 L of dialysis fluid per week. Dialysis water and ultrapure dialysis fluids have been established as a prerequisite for online convective therapies (namely haemodiafiltration), to improve biocompatibility of the dialysis system and to reduce inflammation profile of the dialysis patients. The microbial quality of dialysis water should be monitored regularly to demonstrate the effectiveness of the disinfection protocol. Current water and dialysis fluids microbial quality assessment is typically done via heterotrophic plate counts (HPC) and endotoxins analysis. Plate counts methodology provides information on the microbial content of the water only after a considerable incubation time (typically 7 days). Flow cytometry (FCM), as a rapid alternative method, provides the possibility of real-time corrective actions and greater patient safety. In this study, we compared the outcomes of dialysis water microbial quality in an existing dialysis clinic, using two different measurement methods, HPC and FCM, to test the possible benefits of applying FCM as a valid alternative method for dialysis water microbial monitoring. We conclude that FCM offers higher sensitivity than HPC for microbial monitoring of dialysis water, potentially enabling earlier corrective actions. More extensive and larger studies are needed, namely, to evaluate the possible added value of FCM method in dialysis fluids monitoring. If the FCM method is confirmed, it will be necessary to establish maximum allowable levels and typical action levels for dialysis water and dialysis fluids quality when using FCM.

Scientific ReportsVol. 15(1)
Université de Montpellier (FR), NephroCare (ES), Fresenius Medical Care (Germany) (DE)
Clean water and sanitation
Openalex Percentile: Top 21%
Biosensors and Analytical Detection
1.35
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.