Sensitive gas spectroscopy method for real-time determination of urease activity <i>via</i> ammonia production

In this study we propose the use of a laser-based photoacoustic spectrometer as a new method to investigate the kinetics of ammonia (NH<sub>3</sub>) emission from the hydrolysis of urea (H<sub>2</sub>N-CO-NH<sub>2</sub>) in the presence of urease. Experiments explored the effects of varying the amounts of water and urease on nitrogen (N) loss from urea aqueous solutions. A linear increase in N-NH<sub>3</sub> loss and the maximum emission rate (<i>r</i><sub>NH<sub>3</sub></sub>) was observed with increasing certified urease concentrations. Specifically, the addition of 10 units of urease resulted in an N loss of 8.1%, with a sensitivity of approximately 0.8% per unit of urease, and reached 12.8 μmol min<sup>-1</sup> with a sensitivity of 1.1 μmol min<sup>-1</sup> per unit of urease for <i>r</i><sub>NH<sub>3</sub></sub>. These relationships enabled the estimation of urease quantities in commercial soy flour extracts. Variations in water and urease proportions revealed that maximum NH<sub>3</sub> emissions occurred within the first 2-5 h, with the highest N-NH<sub>3</sub> loss value attaining (9 ± 1)% for samples containing 2.0 mL soy flour extracts and additional water. For urease concentration assays, N-NH<sub>3</sub> loss and <i>r</i><sub>NH<sub>3</sub></sub> were (14.4 ± 0.1)% and (25.3 ± 0.1) μmol min<sup>-1</sup>, respectively, with 4.0 mL of soy flour extract. The results underscored the dominant influence of urease compared to that of water in urea hydrolysis. The PA spectrometer demonstrated sufficient sensitivity for detecting NH<sub>3</sub>, rendering it a promising tool for studying urease activity in urea decomposition. Future work could explore this system under crop field conditions to elucidate the roles of urease and water in the cycling of nutrients within agroecosystems.

Authors

Institutions

Publication Details

Journal
Analytical Methods
Published
2025-01-01
DOI
https://doi.org/10.1039/d4ay02270j
Primary Topic
Gas Sensing Nanomaterials and Sensors
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Sensitive gas spectroscopy method for real-time determination of urease activity via ammonia production

Marcelo Gomes da Silva, Bruno José Rodrígues Alves, Guilherme Rodrigues Lima, Leonardo Mota et al.
Analytical Methods
Gas Sensing Nanomaterials and Sensors
article

Sensitive gas spectroscopy method for real-time determination of urease activity via ammonia production

Marcelo Gomes da Silva, Bruno José Rodrígues Alves, Guilherme Rodrigues Lima, Leonardo Mota, Dominik Clara Luz Lopes, Letícia Andrade Simões Lopes
article en

Abstract

In this study we propose the use of a laser-based photoacoustic spectrometer as a new method to investigate the kinetics of ammonia (NH<sub>3</sub>) emission from the hydrolysis of urea (H<sub>2</sub>N-CO-NH<sub>2</sub>) in the presence of urease. Experiments explored the effects of varying the amounts of water and urease on nitrogen (N) loss from urea aqueous solutions. A linear increase in N-NH<sub>3</sub> loss and the maximum emission rate (<i>r</i><sub>NH<sub>3</sub></sub>) was observed with increasing certified urease concentrations. Specifically, the addition of 10 units of urease resulted in an N loss of 8.1%, with a sensitivity of approximately 0.8% per unit of urease, and reached 12.8 μmol min<sup>-1</sup> with a sensitivity of 1.1 μmol min<sup>-1</sup> per unit of urease for <i>r</i><sub>NH<sub>3</sub></sub>. These relationships enabled the estimation of urease quantities in commercial soy flour extracts. Variations in water and urease proportions revealed that maximum NH<sub>3</sub> emissions occurred within the first 2-5 h, with the highest N-NH<sub>3</sub> loss value attaining (9 ± 1)% for samples containing 2.0 mL soy flour extracts and additional water. For urease concentration assays, N-NH<sub>3</sub> loss and <i>r</i><sub>NH<sub>3</sub></sub> were (14.4 ± 0.1)% and (25.3 ± 0.1) μmol min<sup>-1</sup>, respectively, with 4.0 mL of soy flour extract. The results underscored the dominant influence of urease compared to that of water in urea hydrolysis. The PA spectrometer demonstrated sufficient sensitivity for detecting NH<sub>3</sub>, rendering it a promising tool for studying urease activity in urea decomposition. Future work could explore this system under crop field conditions to elucidate the roles of urease and water in the cycling of nutrients within agroecosystems.

Analytical MethodsVol. 17(17)
Brazilian Agricultural Research Corporation (BR), State University of Norte Fluminense (BR), Empresa de Pesquisa Agropecuária do Estado do Rio de Janeiro (BR), Universidade Federal do Espírito Santo (BR)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior, Conselho Nacional de Desenvolvimento Científico e Tecnológico, Fundação Carlos Chagas Filho de Amparo à Pesquisa do Estado do Rio de Janeiro
Clean water and sanitation
Openalex Percentile: Top 94%
Gas Sensing Nanomaterials and Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.