Dual‐Array Mixed Magnetic Metamaterials via Strong Magnetic Coupling Based Wireless Power Transfer System for Cardiac Pacemakers

ABSTRACT To address the issue of coil misalignment in wireless power transfer (WPT) systems for cardiac pacemakers, which leads to fluctuations in power transmission efficiency (PTE) and reduce system stability, this paper proposes a WPT system operating at 150 kHz based on dual‐array mixed magnetic metamaterials (Mix‐MNG). First, three types of resonant units with different magnetic permeability were designed based on the quality factor theory of metamaterials. The arithmetic variation method was employed to reduce the ohmic losses of hexagonal resonant units, optimizing their quality factor. Second, a dual‐array structure of Mix‐MNG was constructed based on the varying magnetic field refraction capabilities of units with different magnetic permeability. The system's transmission performance and misalignment tolerance were analyzed through simulations and experiments. Third, a human body model was created in COMSOL to evaluate the system's safety. Experimental results show that at a transmission distance of 20 mm, the PTE of the system incorporating the dual‐array Mix‐MNG increased from 30.7% to 73.2%. Furthermore, within a 30 mm misalignment range of the single array Mix‐MNG and the receiving coil, the system maintained transmission efficiencies of 41.2%–58.1% and 30.3%–56.6%. During a 30‐min charging test, the tissue SAR values and temperature rise remained within safe thresholds.

Authors

Institutions

Publication Details

Journal
International Journal of Circuit Theory and Applications
Published
2025-04-14
DOI
https://doi.org/10.1002/cta.4550
Primary Topic
Wireless Power Transfer Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dual‐Array Mixed Magnetic Metamaterials via Strong Magnetic Coupling Based Wireless Power Transfer System for Cardiac Pacemakers

Jishen Peng, Feiyu Zhu, Souleiman Hassan Guirreh, Weihua Chen
International Journal of Circuit Theory and Applications
Wireless Power Transfer Systems
article

Dual‐Array Mixed Magnetic Metamaterials via Strong Magnetic Coupling Based Wireless Power Transfer System for Cardiac Pacemakers

Jishen Peng, Feiyu Zhu, Souleiman Hassan Guirreh, Weihua Chen
article en

Abstract

ABSTRACT To address the issue of coil misalignment in wireless power transfer (WPT) systems for cardiac pacemakers, which leads to fluctuations in power transmission efficiency (PTE) and reduce system stability, this paper proposes a WPT system operating at 150 kHz based on dual‐array mixed magnetic metamaterials (Mix‐MNG). First, three types of resonant units with different magnetic permeability were designed based on the quality factor theory of metamaterials. The arithmetic variation method was employed to reduce the ohmic losses of hexagonal resonant units, optimizing their quality factor. Second, a dual‐array structure of Mix‐MNG was constructed based on the varying magnetic field refraction capabilities of units with different magnetic permeability. The system's transmission performance and misalignment tolerance were analyzed through simulations and experiments. Third, a human body model was created in COMSOL to evaluate the system's safety. Experimental results show that at a transmission distance of 20 mm, the PTE of the system incorporating the dual‐array Mix‐MNG increased from 30.7% to 73.2%. Furthermore, within a 30 mm misalignment range of the single array Mix‐MNG and the receiving coil, the system maintained transmission efficiencies of 41.2%–58.1% and 30.3%–56.6%. During a 30‐min charging test, the tissue SAR values and temperature rise remained within safe thresholds.

International Journal of Circuit Theory and ApplicationsVol. 53(12)
Liaoning Technical University (CN)
Openalex Percentile: Top 94%
Wireless Power Transfer Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Dual‐Array Mixed Magnetic Metamaterials via Strong Magnetic Coupling Based Wireless Power Transfer System for Cardiac Pacemakers — Jishen Peng, Feiyu Zhu, et al. · International Journal of Circuit Theory and Applications (2025) | TGRS Research Map | TGRS