Fast and complete removal of quinolones from actual water matrices by activated peroxymonocarbonate via magnetic Co–Cu in carbon nanofibers

Abstract The extensive use of quinolones leads to serious residues in different water matrices and consequent ecological risks. Magnetic Co–Cu incorporated in‐situ in carbon nanofibers (Co–Cu/CNFs) were prepared for peroxymonocarbonate (PMC) activation during quinolone degradation. The as‐synthesized nanocomposites exhibited a high aspect ratio, large specific surface area (283.6 m 2 · g −1 ), encapsulated Co and Cu nanoparticles and magnetic response (6.2 emu · g −1 ). Complete pefloxacin degradation can be achieved in 8 min in the Co–Cu/CNFs activated PMC system, and six other commonly used and detected quinolones can also be completely removed in approximately half an hour. Furthermore, ciprofloxacin can be completely decomposed within 50 min in different actual water matrices. The remarkable catalytic activities of Co–Cu/CNFs might be attributed to the increasing conductivity and electron transfer capability according to electrochemical impedance spectroscopy. The Co–Cu/CNFs activated PMC system is superior to other counterpart activated peroxide systems in terms of faster removal rates, less leakage of metal ions and greater proportions of heterogeneous catalytic reactions. Singlet oxygen was the primary contributor to ciprofloxacin degradation, followed by hydroxyl, carbonate and superoxide anion radicals. The pharmacophores of 26 ciprofloxacin transformation products were converted by reactive species, including 81% pharmacophore removal which is beneficial for subsequent natural attenuation or biological treatment.

Authors

Institutions

Publication Details

Journal
Rare Metals
Published
2025-04-14
DOI
https://doi.org/10.1007/s12598-024-03189-4
Citations
6
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
4.38

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fast and complete removal of quinolones from actual water matrices by activated peroxymonocarbonate via magnetic Co–Cu in carbon nanofibers

Wei Du, Lulu Kuang, Bo‐Tao Zhang, J. W. Zhao et al.
6 citations
Rare Metals
Electrochemical sensors and biosensors
4.38
article

Fast and complete removal of quinolones from actual water matrices by activated peroxymonocarbonate via magnetic Co–Cu in carbon nanofibers

Wei Du, Lulu Kuang, Bo‐Tao Zhang, J. W. Zhao, Haoqi Yang, Juin Yau Lim, Qianru Zhang, Zhuo Chen
article en
6 citations

Abstract

Abstract The extensive use of quinolones leads to serious residues in different water matrices and consequent ecological risks. Magnetic Co–Cu incorporated in‐situ in carbon nanofibers (Co–Cu/CNFs) were prepared for peroxymonocarbonate (PMC) activation during quinolone degradation. The as‐synthesized nanocomposites exhibited a high aspect ratio, large specific surface area (283.6 m 2 · g −1 ), encapsulated Co and Cu nanoparticles and magnetic response (6.2 emu · g −1 ). Complete pefloxacin degradation can be achieved in 8 min in the Co–Cu/CNFs activated PMC system, and six other commonly used and detected quinolones can also be completely removed in approximately half an hour. Furthermore, ciprofloxacin can be completely decomposed within 50 min in different actual water matrices. The remarkable catalytic activities of Co–Cu/CNFs might be attributed to the increasing conductivity and electron transfer capability according to electrochemical impedance spectroscopy. The Co–Cu/CNFs activated PMC system is superior to other counterpart activated peroxide systems in terms of faster removal rates, less leakage of metal ions and greater proportions of heterogeneous catalytic reactions. Singlet oxygen was the primary contributor to ciprofloxacin degradation, followed by hydroxyl, carbonate and superoxide anion radicals. The pharmacophores of 26 ciprofloxacin transformation products were converted by reactive species, including 81% pharmacophore removal which is beneficial for subsequent natural attenuation or biological treatment.

Rare MetalsVol. 44(9)
Beijing Normal University (CN), Institute of Agricultural Resources and Regional Planning (CN), Agilent Technologies (Australia) (AU), Korea University (JP)
National Key Research and Development Program of China
Clean water and sanitation
Openalex Percentile: Top 6%
Electrochemical sensors and biosensors
4.38
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.