Design and Analysis of Current Differential Protection of T‐Connection Line Employing Power Internet‐of‐Things <scp>B5G</scp> Networks

The successful operation of current differential protection (CDP) requires the support of the real‐time and reliable power Internet‐of‐Things (PIoT) communication networks. Particularly in the future power distribution networks modeled as T‐connection line topology, the current 5G standard based on the configurable frequency division multiplexing access (OFDMA) cannot perfectly meet the strict reliability requirement in data communication due to the lack of a robust signal processing strategy. This paper is concerned with improving the performance of the T‐connection CDP service via the novel 5G and beyond (5G/B5G) system design. First, a reliable PIoT B5G system based on hopped‐subcarrier and configurable OFDMA (FH/OFDMA) is proposed to improve the reliable connectivity for multiple CDP nodes. Second, the impact of the synchronization error and the data error of the proposed communication link on the performance of CDP, including mal‐operation rate and refusal operation rate, are studied via signal analysis. The numerical analysis and simulation results verify that, compared with the current OFDMA‐based 5G network, the proposed scheme boosts the reliability of CDP (i.e., lower mal‐operation rate and refusal operation rate) benefited from the new communication design. The proposed FH/OFDMA‐based PIoT B5G network is capable of combating the synchronization error and the data error over the complex electromagnetic environment, which enhances the robustness of the information exchange among multiple CDP nodes. © 2025 Institute of Electrical Engineers of Japan and Wiley Periodicals LLC.

Authors

Institutions

Publication Details

Journal
IEEJ Transactions on Electrical and Electronic Engineering
Published
2025-04-13
DOI
https://doi.org/10.1002/tee.70018
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and Analysis of Current Differential Protection of T‐Connection Line Employing Power Internet‐of‐Things B5G Networks

Qi Zeng, Xiaoyu Peng, Jun Zhong
IEEJ Transactions on Electrical and Electronic Engineering
Power Systems Fault Detection
article

Design and Analysis of Current Differential Protection of T‐Connection Line Employing Power Internet‐of‐Things B5G Networks

Qi Zeng, Xiaoyu Peng, Jun Zhong
article en

Abstract

The successful operation of current differential protection (CDP) requires the support of the real‐time and reliable power Internet‐of‐Things (PIoT) communication networks. Particularly in the future power distribution networks modeled as T‐connection line topology, the current 5G standard based on the configurable frequency division multiplexing access (OFDMA) cannot perfectly meet the strict reliability requirement in data communication due to the lack of a robust signal processing strategy. This paper is concerned with improving the performance of the T‐connection CDP service via the novel 5G and beyond (5G/B5G) system design. First, a reliable PIoT B5G system based on hopped‐subcarrier and configurable OFDMA (FH/OFDMA) is proposed to improve the reliable connectivity for multiple CDP nodes. Second, the impact of the synchronization error and the data error of the proposed communication link on the performance of CDP, including mal‐operation rate and refusal operation rate, are studied via signal analysis. The numerical analysis and simulation results verify that, compared with the current OFDMA‐based 5G network, the proposed scheme boosts the reliability of CDP (i.e., lower mal‐operation rate and refusal operation rate) benefited from the new communication design. The proposed FH/OFDMA‐based PIoT B5G network is capable of combating the synchronization error and the data error over the complex electromagnetic environment, which enhances the robustness of the information exchange among multiple CDP nodes. © 2025 Institute of Electrical Engineers of Japan and Wiley Periodicals LLC.

IEEJ Transactions on Electrical and Electronic EngineeringVol. 20(9)
Sichuan University (CN)
Ministry of Industry and Information Technology of the People's Republic of China
Openalex Percentile: Top 92%
Power Systems Fault Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Design and Analysis of Current Differential Protection of T‐Connection Line Employing Power Internet‐of‐Things <scp>B5G</scp> Networks — Qi Zeng, Xiaoyu Peng, et al. · IEEJ Transactions on Electrical and Electronic Engineering (2025) | TGRS Research Map | TGRS