Measurement of static and dynamic pupillary characteristics after implantable collamer lens by sirius anterior segment analysis system

This study investigated static and dynamic pupillometry changes before and after ICL V4c implantation under varying light conditions. A prospective study of 210 high myopia patients undergoing V4c ICL implantation was conducted. Pupillometry was performed preoperatively and at 2 weeks, 1 month, and 3 months postoperatively using the Sirius anterior eye segment analysis system (CSO, Florence, Italy). Static parameters (pupil diameter at scotopic, mesopic, and photopic levels) and dynamic parameters (minimum pupil diameter post-light stimulation and dilation velocity) were evaluated. Postoperatively, pupil diameter (PD) decreased significantly under scotopic, mesopic, and photopic conditions but returned to preoperative levels by 1-3 months. Minimum PD after light stimulation and dilation velocity remained unchanged. Pupil center coordinates shifted inferotemporally and gradually approached the corneal center. Scotopic and photopic vaults positively correlated with PD under all light conditions but showed no correlation with minimum PD or dilation velocity. ICL V4c implantation transiently reduces pupil diameter under all light conditions, with recovery to baseline by 1-3 months. Pupil center shifts inferotemporally and approaches the corneal center, while vaults correlate with PD but not dynamic pupillary parameters. The ethics committee of Zhengzhou University's First Affiliated Hospital gave its approval to this study (2024-KY-0561).

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-04-13
DOI
https://doi.org/10.1038/s41598-025-98183-w
Primary Topic
Corneal surgery and disorders
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Measurement of static and dynamic pupillary characteristics after implantable collamer lens by sirius anterior segment analysis system

Yanhui Bai, Jing Yang, Weiqun Wang, Wentao Liu
Scientific Reports
Corneal surgery and disorders
article

Measurement of static and dynamic pupillary characteristics after implantable collamer lens by sirius anterior segment analysis system

Yanhui Bai, Jing Yang, Weiqun Wang, Wentao Liu
article en

Abstract

This study investigated static and dynamic pupillometry changes before and after ICL V4c implantation under varying light conditions. A prospective study of 210 high myopia patients undergoing V4c ICL implantation was conducted. Pupillometry was performed preoperatively and at 2 weeks, 1 month, and 3 months postoperatively using the Sirius anterior eye segment analysis system (CSO, Florence, Italy). Static parameters (pupil diameter at scotopic, mesopic, and photopic levels) and dynamic parameters (minimum pupil diameter post-light stimulation and dilation velocity) were evaluated. Postoperatively, pupil diameter (PD) decreased significantly under scotopic, mesopic, and photopic conditions but returned to preoperative levels by 1-3 months. Minimum PD after light stimulation and dilation velocity remained unchanged. Pupil center coordinates shifted inferotemporally and gradually approached the corneal center. Scotopic and photopic vaults positively correlated with PD under all light conditions but showed no correlation with minimum PD or dilation velocity. ICL V4c implantation transiently reduces pupil diameter under all light conditions, with recovery to baseline by 1-3 months. Pupil center shifts inferotemporally and approaches the corneal center, while vaults correlate with PD but not dynamic pupillary parameters. The ethics committee of Zhengzhou University's First Affiliated Hospital gave its approval to this study (2024-KY-0561).

Scientific ReportsVol. 15(1)
First Affiliated Hospital of Zhengzhou University (CN)
Natural Science Foundation of Henan Province
Openalex Percentile: Top 88%
Corneal surgery and disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Measurement of static and dynamic pupillary characteristics after implantable collamer lens by sirius anterior segment analysis system — Yanhui Bai, Jing Yang, et al. · Scientific Reports (2025) | TGRS Research Map | TGRS