Integrated Geophysical and Geochemical Evaluation of Groundwater Vulnerability to Open Dumpsite: A Case Study of Part of Zango-Daji Groundwater, Lokoja, North Central Nigeria.

This study aimed to assess the impact of dumpsite leachate plume on groundwater in Zango Daji, within Latitude 7⁰46’00”N to 7⁰50’00”N and Longitude 6⁰37’00”E to 6⁰41’00”E. It utilized geophysical methods, including six electrical imaging lines (three 2D resistivity and three Induced Polarization), nine Vertical Electrical Sounding (VES) data points, and groundwater analysis. The data were quantitatively and qualitatively processed using RES2DINV, WINRESIST and SURFER software. 2D resistivity and IP profiles taken at the dumpsite showed low resistivity (11.7–51.8 Ωm) and chargeability (-0.7 to 1.45 msec) in the topsoil and fractured basement zones, indicating leachate migration pathways. A profile 100 m west of the dumpsite showed moderate resistivity (11–422 Ωm) and chargeability (2–6.2 msecs), suggesting a clayey lithologic cover, which act to impede leachate plume flow to the subsurface groundwater. The eastern profile had lower resistivity (29–299 Ωm) and chargeability (>2.7 msec), indicating contamination. The VES results aligned with the 2D resistivity findings. Geochemical analysis of five water samples revealed slightly acidic to alkaline conditions, with cation concentrations following the order Ca > Na > Mg > K and anion concentrations Cl > SO4 > HCO3. Most physiochemical parameters were within WHO (2017) limits, except for chloride, TDS, COD, and lead, which exceeded limits at and east of the dumpsite. The eastern area’s low resistivity and chargeability were linked to elevated physiochemical parameters, likely due to contamination from the dumpsite. Geochemical plots indicated chlorine dominance in groundwater. The study concluded that groundwater quality was affected by anthropogenic activities rather than natural rock-water interactions, with contamination more evident in the eastern zone.

Authors

Publication Details

Journal
International journal of research and scientific innovation
Published
2025-01-01
DOI
https://doi.org/10.51244/ijrsi.2025.12030063
Primary Topic
Geochemistry and Geologic Mapping
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Integrated Geophysical and Geochemical Evaluation of Groundwater Vulnerability to Open Dumpsite: A Case Study of Part of Zango-Daji Groundwater, Lokoja, North Central Nigeria.

Chukwudi C. Ezeh, Danga Onimisi Abdulmalik
International journal of research and scientific innovation
Geochemistry and Geologic Mapping
article

Integrated Geophysical and Geochemical Evaluation of Groundwater Vulnerability to Open Dumpsite: A Case Study of Part of Zango-Daji Groundwater, Lokoja, North Central Nigeria.

Chukwudi C. Ezeh, Danga Onimisi Abdulmalik
article en

Abstract

This study aimed to assess the impact of dumpsite leachate plume on groundwater in Zango Daji, within Latitude 7⁰46’00”N to 7⁰50’00”N and Longitude 6⁰37’00”E to 6⁰41’00”E. It utilized geophysical methods, including six electrical imaging lines (three 2D resistivity and three Induced Polarization), nine Vertical Electrical Sounding (VES) data points, and groundwater analysis. The data were quantitatively and qualitatively processed using RES2DINV, WINRESIST and SURFER software. 2D resistivity and IP profiles taken at the dumpsite showed low resistivity (11.7–51.8 Ωm) and chargeability (-0.7 to 1.45 msec) in the topsoil and fractured basement zones, indicating leachate migration pathways. A profile 100 m west of the dumpsite showed moderate resistivity (11–422 Ωm) and chargeability (2–6.2 msecs), suggesting a clayey lithologic cover, which act to impede leachate plume flow to the subsurface groundwater. The eastern profile had lower resistivity (29–299 Ωm) and chargeability (>2.7 msec), indicating contamination. The VES results aligned with the 2D resistivity findings. Geochemical analysis of five water samples revealed slightly acidic to alkaline conditions, with cation concentrations following the order Ca > Na > Mg > K and anion concentrations Cl > SO4 > HCO3. Most physiochemical parameters were within WHO (2017) limits, except for chloride, TDS, COD, and lead, which exceeded limits at and east of the dumpsite. The eastern area’s low resistivity and chargeability were linked to elevated physiochemical parameters, likely due to contamination from the dumpsite. Geochemical plots indicated chlorine dominance in groundwater. The study concluded that groundwater quality was affected by anthropogenic activities rather than natural rock-water interactions, with contamination more evident in the eastern zone.

International journal of research and scientific innovationVol. XII(III)
Openalex Percentile: Top 97%
Geochemistry and Geologic Mapping
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.