Survey of Radiation Exposure During Cyclotron Operation for PET Radiopharmaceutical Production at NINMAS

Regular monitoring, proper shielding, and attention to safety procedures are all necessary for radiation safety in cyclotron facilities to reduce exposure and ensure regulatory compliance. This study investigates the radiation safety precautions taken at the National Institute of Nuclear Medicine and Allied Sciences (NINMAS) of Bangladesh Atomic Energy Commission (BAEC), during the operation of 18/9 MeV IBA Cyclone and synthesis of 18F-2-fluoro-2-deoxyglucose (18F-FDG). Portable survey meters and fixed Geiger-Muller (GM) counters were used to measure exposed dose of radiation in highly hazardous locations such as the cyclotron control room close to the vault and hot cell close to the synthesizers. Measurements were thoroughly carried out before, during, and following cyclotron operations. The findings showed that the hot cell room experienced radiation levels of 2.3 μSv/h during the synthesis of 18F-FDG, and the corridor vault experienced peak radiation levels of 2.0 μSv/h during the production of 18F. There was still activity present since post-operation values were higher than the baseline. When handling 18F-FDG, additional measurements at L-bench positions demonstrated the value of shielding and distance, with unshielded dose rates rising to 1.58 mSv/h. Safety precautions including radiation workers distance guidelines, ALARA (As Low As Reasonably Achievable) principles, and real-time monitoring were implemented to provide radiation protection. The results highlight the necessity of constant radiation monitoring, sufficient shielding, and rigorous adherence to radiation safety procedures to reduce occupational exposure and preserve regulatory compliance in medical cyclotron facilities. Bangladesh J. Nuclear Med. 28(1): 68-74, 2025

Authors

Institutions

Publication Details

Journal
Bangladesh Journal of Nuclear Medicine
Published
2025-04-13
DOI
https://doi.org/10.3329/bjnm.v28i1.79477
Primary Topic
Radiopharmaceutical Chemistry and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Survey of Radiation Exposure During Cyclotron Operation for PET Radiopharmaceutical Production at NINMAS

Hasan Mehdi, Sanjida Islam, Md. Shorif Hossan, Priyanka Podder et al.
Bangladesh Journal of Nuclear Medicine
Radiopharmaceutical Chemistry and Applications
article

Survey of Radiation Exposure During Cyclotron Operation for PET Radiopharmaceutical Production at NINMAS

Hasan Mehdi, Sanjida Islam, Md. Shorif Hossan, Priyanka Podder, Md. Jashim Uddin, Nahid Hossain, Md Shohag Mia, M. Mustafa Mamun, Sanchoy Chandra Biswasarma, Md Saiful Islam, Muhtasim Kadir, Mohammad Anwar Ul Azim, Ferdoushi Begum, Nur E Alam Siddiqee
article en

Abstract

Regular monitoring, proper shielding, and attention to safety procedures are all necessary for radiation safety in cyclotron facilities to reduce exposure and ensure regulatory compliance. This study investigates the radiation safety precautions taken at the National Institute of Nuclear Medicine and Allied Sciences (NINMAS) of Bangladesh Atomic Energy Commission (BAEC), during the operation of 18/9 MeV IBA Cyclone and synthesis of 18F-2-fluoro-2-deoxyglucose (18F-FDG). Portable survey meters and fixed Geiger-Muller (GM) counters were used to measure exposed dose of radiation in highly hazardous locations such as the cyclotron control room close to the vault and hot cell close to the synthesizers. Measurements were thoroughly carried out before, during, and following cyclotron operations. The findings showed that the hot cell room experienced radiation levels of 2.3 μSv/h during the synthesis of 18F-FDG, and the corridor vault experienced peak radiation levels of 2.0 μSv/h during the production of 18F. There was still activity present since post-operation values were higher than the baseline. When handling 18F-FDG, additional measurements at L-bench positions demonstrated the value of shielding and distance, with unshielded dose rates rising to 1.58 mSv/h. Safety precautions including radiation workers distance guidelines, ALARA (As Low As Reasonably Achievable) principles, and real-time monitoring were implemented to provide radiation protection. The results highlight the necessity of constant radiation monitoring, sufficient shielding, and rigorous adherence to radiation safety procedures to reduce occupational exposure and preserve regulatory compliance in medical cyclotron facilities. Bangladesh J. Nuclear Med. 28(1): 68-74, 2025

Bangladesh Journal of Nuclear MedicineVol. 28(1)
Bangladesh Medical University (BD), Bangladesh Livestock Research Institute (BD), National Institute of Nuclear Medicine & Allied Sciences (BD), Bangladesh Atomic Energy Commission (BD)
Openalex Percentile: Top 89%
Radiopharmaceutical Chemistry and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.