Baroreflex and autonomic responses to two equated isometric resistance exercise protocols in females

Abstract Different resistance exercise set configurations seem to lead to distinct hemodynamic, baroreflex and autonomic responses. Nevertheless, both the baroreflex and the autonomic reactivity to an equated work-to-rest ratio (W:R-equated) isometric exercise (IE) session in females still must be clarified. Thus, the present work investigated the autonomic and baroreflex responses of two W:R-equated isometric exercise sessions in female participants. Nine healthy females (25 ± 3 years) performed two isometric protocols equated by W:R with 30% 1-RM - a long set configuration (LSC): 4 sets x 2 min isometric x 2 min rest; and a short set configuration (SSC): 16 sets x 30 s isometric x 24s rest. Blood pressure (BP) and cardiac intervals were monitored by photoplesthysmography and electrocardiogram before, during and after (immediately, 30 and 60 min) exercise. The time domain parameters and frequency domain measures of the heart rate variability were calculated along with the baroreflex gain and effectiveness. A two-way repeated measures ANOVA was applied. Both protocols evoked a reduction in the baroreflex gain, whereas the LSC gain reduction lasted longer (30 and 60 minutes). Only the SSC was able to lower the root mean square of successive differences between normal heart beats (RMSSD) during exercise, when compared to pre-session values (p < 0.05). The standard deviation of the normal-to-normal interval (SDNN) increased during exercise with the LSC protocol (p<0.05). The high-frequency (HF) band only decreased during exercise using the SSC protocol (p < 0.05), while the LF/HF ratio was also only elevated in the SSC during exercise (p<0.05). The LSC evoked more prolonged reductions in the baroreflex gain, while the SSC protocol caused a greater disturbance in cardiac autonomic modulation.

Authors

Institutions

Publication Details

Journal
Brazilian Journal of Kinanthropometry and Human Performance
Published
2025-01-01
DOI
https://doi.org/10.1590/1980-0037.2025v27e99261
Primary Topic
Heart Rate Variability and Autonomic Control
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Baroreflex and autonomic responses to two equated isometric resistance exercise protocols in females

Guilherme Fleury Fina Speretta, Letícia Nascimento Santos Neves, Carlos Brendo Ferreira Reis, Igor Alves Mello et al.
Brazilian Journal of Kinanthropometry and Human Performance
Heart Rate Variability and Autonomic Control
article

Baroreflex and autonomic responses to two equated isometric resistance exercise protocols in females

Guilherme Fleury Fina Speretta, Letícia Nascimento Santos Neves, Carlos Brendo Ferreira Reis, Igor Alves Mello, Victor Hugo Gasparini Neto, Luciana Carletti, Lucas Rangel Affonso de Miranda, Richard Diego Leite
article en

Abstract

Abstract Different resistance exercise set configurations seem to lead to distinct hemodynamic, baroreflex and autonomic responses. Nevertheless, both the baroreflex and the autonomic reactivity to an equated work-to-rest ratio (W:R-equated) isometric exercise (IE) session in females still must be clarified. Thus, the present work investigated the autonomic and baroreflex responses of two W:R-equated isometric exercise sessions in female participants. Nine healthy females (25 ± 3 years) performed two isometric protocols equated by W:R with 30% 1-RM - a long set configuration (LSC): 4 sets x 2 min isometric x 2 min rest; and a short set configuration (SSC): 16 sets x 30 s isometric x 24s rest. Blood pressure (BP) and cardiac intervals were monitored by photoplesthysmography and electrocardiogram before, during and after (immediately, 30 and 60 min) exercise. The time domain parameters and frequency domain measures of the heart rate variability were calculated along with the baroreflex gain and effectiveness. A two-way repeated measures ANOVA was applied. Both protocols evoked a reduction in the baroreflex gain, whereas the LSC gain reduction lasted longer (30 and 60 minutes). Only the SSC was able to lower the root mean square of successive differences between normal heart beats (RMSSD) during exercise, when compared to pre-session values (p < 0.05). The standard deviation of the normal-to-normal interval (SDNN) increased during exercise with the LSC protocol (p<0.05). The high-frequency (HF) band only decreased during exercise using the SSC protocol (p < 0.05), while the LF/HF ratio was also only elevated in the SSC during exercise (p<0.05). The LSC evoked more prolonged reductions in the baroreflex gain, while the SSC protocol caused a greater disturbance in cardiac autonomic modulation.

Brazilian Journal of Kinanthropometry and Human PerformanceVol. 27
Universidade Federal de Santa Catarina (BR), Universidade Federal do Espírito Santo (BR)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior, Conselho Nacional de Desenvolvimento Científico e Tecnológico, Fundação de Amparo à Pesquisa e Inovação do Espírito Santo
Openalex Percentile: Top 87%
Heart Rate Variability and Autonomic Control
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.