Comparison between traditional measures and airway column in postextubation stridor

Background While the majority of stridor cases do not necessitate medical treatment, there are instances where it may result in reintubation due to upper airway obstruction. Aim This study aimed to evaluate the effectiveness of traditional assessment methods versus airway column width measurements in predicting postextubation stridor among patients in an emergency ICU who are on mechanical ventilation. Patients and methods This study was designed as a prospective randomized comparative investigation involving 90 patients, aged 18–60 years, representing both sexes, who had undergone intubation and mechanical ventilation for a duration exceeding 24 h. The participants were randomly divided into two equal cohorts: group A underwent a cuff leak test to assess air leaks, using appropriately sized cuffed endotracheal tubes, while group B had their air column width evaluated via ultrasound to measure edema. Results Cuff leak volume and percentage can significantly predict patients developed postextubation stridor ( P <0.001 and area under the curve=0.784) at a cut-off less than or equal to 129 ml for the volume and less than or equal to 13% for the percentage with 83.33% sensitivity, 76.92% specificity, 35.7% positive predictive value, and 96.8% negative predictive value. Air column width difference can significantly predict patients developed postextubation stridor ( P <0.001 and area under the curve=0.872) at cut-off less than 0.9 with 75% sensitivity, 87.8% specificity, 37.5% positive predictive value, and 97.3% negative predictive value. Conclusions Laryngeal ultrasonography is a reliable, noninvasive alternative for assessing vocal cord functionality, laryngeal anatomy, and airflow dynamics in intubated patients compared to the cuff leak test.

Authors

Institutions

Publication Details

Journal
Tanta Medical Journal
Published
2025-04-01
DOI
https://doi.org/10.4103/tmj.tmj_74_24
Primary Topic
Airway Management and Intubation Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison between traditional measures and airway column in postextubation stridor

Roeya M. Aboelnasr, Atteia Gad Anwar, Sabry M. Amin, Wessam M. Elbhairy
Tanta Medical Journal
Airway Management and Intubation Techniques
article

Comparison between traditional measures and airway column in postextubation stridor

Roeya M. Aboelnasr, Atteia Gad Anwar, Sabry M. Amin, Wessam M. Elbhairy
article en

Abstract

Background While the majority of stridor cases do not necessitate medical treatment, there are instances where it may result in reintubation due to upper airway obstruction. Aim This study aimed to evaluate the effectiveness of traditional assessment methods versus airway column width measurements in predicting postextubation stridor among patients in an emergency ICU who are on mechanical ventilation. Patients and methods This study was designed as a prospective randomized comparative investigation involving 90 patients, aged 18–60 years, representing both sexes, who had undergone intubation and mechanical ventilation for a duration exceeding 24 h. The participants were randomly divided into two equal cohorts: group A underwent a cuff leak test to assess air leaks, using appropriately sized cuffed endotracheal tubes, while group B had their air column width evaluated via ultrasound to measure edema. Results Cuff leak volume and percentage can significantly predict patients developed postextubation stridor ( P <0.001 and area under the curve=0.784) at a cut-off less than or equal to 129 ml for the volume and less than or equal to 13% for the percentage with 83.33% sensitivity, 76.92% specificity, 35.7% positive predictive value, and 96.8% negative predictive value. Air column width difference can significantly predict patients developed postextubation stridor ( P <0.001 and area under the curve=0.872) at cut-off less than 0.9 with 75% sensitivity, 87.8% specificity, 37.5% positive predictive value, and 97.3% negative predictive value. Conclusions Laryngeal ultrasonography is a reliable, noninvasive alternative for assessing vocal cord functionality, laryngeal anatomy, and airflow dynamics in intubated patients compared to the cuff leak test.

Tanta Medical JournalVol. 53(2)
Tanta University Hospital (EG)
Openalex Percentile: Top 86%
Airway Management and Intubation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.