Investigating the effect of icterus interference on a creatinine Roche enzymatic methodology

BackgroundIt is well established that high bilirubin concentrations can lead to erroneous creatinine results when measured by a Jaffe-based method. However, the effects of bilirubin on enzymatic methods appear less well-defined. The Roche Cobas 8000 enzymatic creatinine (CREP2) has an unconjugated bilirubin icterus limit of 20 mg/dL, equivalent to a bilirubin concentration of 342 µmol/L. Many hepatology patients have bilirubin levels much higher than this limit, and laboratories are unable to release creatinine results on these complex patients. This is particularly challenging for patient management, as creatinine is a key test and is a prerequisite for many procedures, imaging studies and treatments.MethodsTwo spiking studies were carried out, the first to define the interference effect of bilirubin on enzymatic creatinine measurement, and the second to see if this interference could be mitigated via dilution. Serum samples (<i>n</i> = 50) were spiked with a concentrated bilirubin solution. Indices, bilirubin and creatinine were measured using the Roche Cobas 8000 c702 automated analyser according to manufacturer instructions.ResultsThe spiking study found a negative linear relationship and as bilirubin concentrations increased, the measured creatinine concentration decreased (R<sup>2</sup> = 0.7828, y = -0.0597x + 15.603). Samples with a bilirubin concentration over 246 µmol/L demonstrated an average 1.48% drop in creatinine concentration per 25 µmol/L increase in bilirubin.ConclusionsA service improvement was applied where creatinine results can be released on samples with a bilirubin concentration up to 550 µmol/L, with an appropriate comment, upon request by the clinician.

Authors

Institutions

Publication Details

Journal
Annals of Clinical Biochemistry International Journal of Laboratory Medicine
Published
2025-04-12
DOI
https://doi.org/10.1177/00045632251337619
Citations
1
Primary Topic
Microbial Metabolism and Applications
Type
article
Field-Weighted Citation Impact
1.23
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Investigating the effect of icterus interference on a creatinine Roche enzymatic methodology

Louise E. Duvall
1 citations
Annals of Clinical Biochemistry International Journal of Laboratory Medicine
Microbial Metabolism and Applications
1.23
article

Investigating the effect of icterus interference on a creatinine Roche enzymatic methodology

Louise E. Duvall
article en
1 citations

Abstract

BackgroundIt is well established that high bilirubin concentrations can lead to erroneous creatinine results when measured by a Jaffe-based method. However, the effects of bilirubin on enzymatic methods appear less well-defined. The Roche Cobas 8000 enzymatic creatinine (CREP2) has an unconjugated bilirubin icterus limit of 20 mg/dL, equivalent to a bilirubin concentration of 342 µmol/L. Many hepatology patients have bilirubin levels much higher than this limit, and laboratories are unable to release creatinine results on these complex patients. This is particularly challenging for patient management, as creatinine is a key test and is a prerequisite for many procedures, imaging studies and treatments.MethodsTwo spiking studies were carried out, the first to define the interference effect of bilirubin on enzymatic creatinine measurement, and the second to see if this interference could be mitigated via dilution. Serum samples (<i>n</i> = 50) were spiked with a concentrated bilirubin solution. Indices, bilirubin and creatinine were measured using the Roche Cobas 8000 c702 automated analyser according to manufacturer instructions.ResultsThe spiking study found a negative linear relationship and as bilirubin concentrations increased, the measured creatinine concentration decreased (R<sup>2</sup> = 0.7828, y = -0.0597x + 15.603). Samples with a bilirubin concentration over 246 µmol/L demonstrated an average 1.48% drop in creatinine concentration per 25 µmol/L increase in bilirubin.ConclusionsA service improvement was applied where creatinine results can be released on samples with a bilirubin concentration up to 550 µmol/L, with an appropriate comment, upon request by the clinician.

Annals of Clinical Biochemistry International Journal of Laboratory MedicineVol. 62(6)
Portsmouth Hospitals NHS Trust (GB)
Openalex Percentile: Top 24%
Microbial Metabolism and Applications
1.23
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Investigating the effect of icterus interference on a creatinine Roche enzymatic methodology — Louise E. Duvall · Annals of Clinical Biochemistry International Journal of Laboratory Medicine (2025) | TGRS Research Map | TGRS