Effect of non-uniform distribution of radioactivity in human body on measurements using HPGe detector based scanning bed whole body counter

In-vivo monitoring of radiation workers for high energy photon emitters is carried out using whole body counters. These are calibrated using standard radioactive sources uniformly distributed in BOMAB phantom. In the case of inhalation intake of Type S compounds, radioactivity is retained in lungs for a long time resulting in non-uniform distribution. In this paper, the effect of non-uniform distribution of activity in human body is studied on the direct measurement using shadow shield bed whole body counter (SSBWBC) with BOMAB and LLNL phantoms. First, the system was calibrated with known amount of 133 Ba, 137 Cs, 60 Co and 40 K uniformly distributed in water filled BOMAB phantom. Then, the system was calibrated with known amount of 152 Eu and 241 Am uniformly distributed in the lungs of LLNL phantom. The multiple gamma energies of radionuclides were used to determine the counting efficiencies for uniformly distributed activity in whole body as well as in the lungs. The study shows when uniform distribution of radionuclides in the whole body is assumed but activity is confined in the lungs only, measured activity is overestimated by 15 to 20 %. This results in similar overestimation in intake and CED. • The scanning type whole body counter was calibrated with known amount of radioactivity uniformly distributed in the BOMAB phantom. • The response of the system was studied for realistic activity distribution in lungs of LLNL phantom. • The effect of non-uniformity due to lung activity deposits on whole body activity measurement, intake and CED estimation is studied.

Authors

Institutions

Publication Details

Journal
Nuclear Engineering and Technology
Published
2025-04-12
DOI
https://doi.org/10.1016/j.net.2025.103636
Citations
2
Primary Topic
Radioactivity and Radon Measurements
Type
article
Field-Weighted Citation Impact
3.08
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of non-uniform distribution of radioactivity in human body on measurements using HPGe detector based scanning bed whole body counter

Lokpati Mishra, Rajesh Sankhla, Pramilla D. Sawant, S. Anilkumar et al.
2 citations
Nuclear Engineering and Technology
Radioactivity and Radon Measurements
3.08
article

Effect of non-uniform distribution of radioactivity in human body on measurements using HPGe detector based scanning bed whole body counter

Lokpati Mishra, Rajesh Sankhla, Pramilla D. Sawant, S. Anilkumar, M. Y. Nadar, Probal Chaudhury, I. S. Singh, P. Prathibha
article en
2 citations

Abstract

In-vivo monitoring of radiation workers for high energy photon emitters is carried out using whole body counters. These are calibrated using standard radioactive sources uniformly distributed in BOMAB phantom. In the case of inhalation intake of Type S compounds, radioactivity is retained in lungs for a long time resulting in non-uniform distribution. In this paper, the effect of non-uniform distribution of activity in human body is studied on the direct measurement using shadow shield bed whole body counter (SSBWBC) with BOMAB and LLNL phantoms. First, the system was calibrated with known amount of 133 Ba, 137 Cs, 60 Co and 40 K uniformly distributed in water filled BOMAB phantom. Then, the system was calibrated with known amount of 152 Eu and 241 Am uniformly distributed in the lungs of LLNL phantom. The multiple gamma energies of radionuclides were used to determine the counting efficiencies for uniformly distributed activity in whole body as well as in the lungs. The study shows when uniform distribution of radionuclides in the whole body is assumed but activity is confined in the lungs only, measured activity is overestimated by 15 to 20 %. This results in similar overestimation in intake and CED. • The scanning type whole body counter was calibrated with known amount of radioactivity uniformly distributed in the BOMAB phantom. • The response of the system was studied for realistic activity distribution in lungs of LLNL phantom. • The effect of non-uniformity due to lung activity deposits on whole body activity measurement, intake and CED estimation is studied.

Nuclear Engineering and TechnologyVol. 57(9)
Bhabha Atomic Research Centre (IN), Homi Bhabha National Institute (IN)
Zero hunger
Openalex Percentile: Top 10%
Radioactivity and Radon Measurements
3.08
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.